课题基金 / 基金详情

Magnetic levitation motor for pediatric cardiac and cardiopulmonary therapies - Phase II

Magnetic levitation motor for pediatric cardiac and cardiopulmonary therapies - Phase II
用于儿科心脏和心肺治疗的磁悬浮电机 - II 期
批准号:
10007196
负责人:
Patrick Thomas Cahalan
金额:
$79.89万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2016
资助国家:
美国
项目状态:
已结题
起止时间:
2016-08-15 至 2022-05-31

项目摘要

项目成果

Patrick Thomas Cahalan的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Abstract This Phase II STTR application represents the main research and development effort for an innovative, low cost, magnetic levitation motor specifically designed for neonatal and pediatric extracorporeal cardiac and cardiopulmonary therapies. Our Phase I efforts demonstrated feasibility of a novel magnetic levitation motor enabling contact-free blood pump impeller operation. Contact-free operation eliminates critical areas of wear as well as reduces heat generation that can contribute to hemolysis and thrombosis. The extracorporeal pediatric market is currently served by a single magnetically levitated blood pump (Abbott PediMag). As with many neonatal and pediatric medical products, the PediMag is a scaled-down version of an adult blood pump that was designed for post-cardiotomy support (Abbott CentriMag). While PediMag has been used successfully in a range of post-cardiotomy support applications, broader usage is limited by several factors including lack of ancillary componentry designed specifically for the pump system (e.g., pediatric blood oxygenator and heat exchanger), complex control algorithms, and a high disposable cost (approximately $8000 per disposable PediMag pump head). To address these shortcomings, we developed an innovative and simplified magnetic levitation motor that eliminates the costly rare earth magnetic elements from the disposable blood-contacting component to the reusable motor stator. Our magnetic levitation motor design also permits simplified control algorithms for improved robustness and reduced power requirements. The levitation motor uses the same impeller and pump housing geometry as currently integrated in Ension’s pediatric cardiopulmonary assist system’s (pCAS) pump-oxygenator and replaces the mechanical bearings, rotating shaft, and blood contacting seal. Our strategy to retain the current pCAS pump geometry both lowers overall development costs and permits the use of existing comprehensive in vitro and in vivo test data for performance comparisons. In Phase I, we completed two acute and one 3-day chronic animal study that demonstrated Phase I feasibility and confirmed a Phase II effort is warranted. Goals in Phase II include motor and controller optimization, expansion of a risk-based design history file (DHF) consistent with FDA’s Quality System Regulation (QSR), and conduct of a range of performance testing to establish safety and reliability. Phase III commercialization activities will include a transfer to manufacturing and verification and validation testing to support a regulatory filing to support clinical trials in pediatric patients with cardiac and/or cardiopulmonary dysfunction.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Magnetic levitation motor for pediatric cardiac and cardiopulmonary therapies - Phase II
  • 批准号:
    10192796
  • 项目类别:
  • 资助金额:
    $65.25万
  • 财政年份:
    2016
  • 负责人:
    Patrick Thomas Cahalan
  • 依托单位:
Infection resistant surface for ventricular assist device (VAD) transcutaneous dr
  • 批准号:
    8453138
  • 项目类别:
  • 资助金额:
    $39.15万
  • 财政年份:
    2013
  • 负责人:
    Patrick Thomas Cahalan
  • 依托单位:
Infection resistant surface for ventricular assist device (VAD) transcutaneous dr
  • 批准号:
    8892504
  • 项目类别:
  • 资助金额:
    $88.07万
  • 财政年份:
    2013
  • 负责人:
    Patrick Thomas Cahalan
  • 依托单位:
Infection resistent coatings for mechanical circulatory support systems (MCSS)
  • 批准号:
    7608524
  • 项目类别:
  • 资助金额:
    $15.77万
  • 财政年份:
    2009
  • 负责人:
    Patrick Thomas Cahalan
  • 依托单位:
海外基金