Dispersion of a Nanoliter Bolus in Microfluidic Co-Flow.

Dispersion of a Nanoliter Bolus in Microfluidic Co-Flow.
复制标题

DOI:
10.1088/0960-1317/24/3/034006
复制
发表时间:
2014-03
期刊:
Journal of micromechanics and microengineering : structures, devices, and systems
影响因子:
--
通讯作者:
Fiering J
Fiering J
中科院分区:
其他
文献类型:
--
作者:
Conway AJ;Saadi WM;Sinatra FL;Kowalski G;Larson D;Fiering J

文献摘要

参考文献

被引文献

相似文献

微流体系统可以在纳升的尺度上进行反应和分析。然而,在这种尺度下,样品交付的不均匀性变得显著。为了确定特定设备所需的基本最小样本量,需要对质量传输有详细的了解。共流层流广泛应用于许多设备中,但通常仅在稳态下使用。由于建立共流稳态会消耗多余的样品体积和时间,因此在瞬态状态下操作设备是有利的,随着共流反应器体积的减小,瞬态状态下的操作设备占主导地位。对共流暂态的分析一直被忽视。在这项工作中,我们描述了一个气动控制的微流体喷射器的制造,该喷射器的构造是将一个离散的50nL丸注入双流共流反应器的一侧。使用染料进行图像分析,在0.5-10μL/min的流速范围内进行注射,为了比较,我们收集了该范围内的共流稳态数据。将图像分析结果与理论和仿真结果进行了比较,以进行设备验证。为了进行评估,我们建立了一个度量,表明在注射量中质量分布近似于稳态共流的程度。使用这种分析,瞬态注射可以在预定义的误差范围内近似于稳态条件,从而可以在减少试剂消耗的情况下直接进行测量。
Microfluidic systems enable reactions and assays on the scale of nanoliters. However, at this scale nonuniformities in sample delivery become significant. To determine the fundamental minimum sample volume required for a particular device, a detailed understanding of mass transport is required. Co-flowing laminar streams are widely used in many devices, but typically only in the steady-state. Because establishing the co-flow steady-state consumes excess sample volume and time, there is a benefit to operating devices in the transient state, which predominates as the volume of the co-flow reactor decreases. Analysis of the co-flow transient has been neglected thus far. In this work we describe the fabrication of a pneumatically controlled microfluidic injector constructed to inject a discrete 50nL bolus into one side of a two-stream co-flow reactor. Using dye for image analysis, injections were performed at a range of flow rates from 0.5-10μL/min, and for comparison we collected the co-flow steady-state data for this range. The results of the image analysis were also compared against theory and simulations for device validation. For evaluation, we established a metric that indicates how well the mass distribution in the bolus injection approximates steady-state co-flow. Using such analysis, transient-state injections can approximate steady-state conditions within predefined errors, allowing straight forward measurements to be performed with reduced reagent consumption.
DOI: 10.1126/science.288.5463.113
发表时间: 2000-04-07
期刊: SCIENCE
影响因子: 56.9
作者:
Unger, MA;Chou, HP;Quake, SR
通讯作者: Quake, SR
DOI: 10.1007/s10404-012-1125-1
发表时间: 2013-07-01
影响因子: 2.8
作者:
Ramji, Ramesh;Roy, Partha
通讯作者: Roy, Partha
DOI: 10.1063/1.126351
发表时间: 2000-04-24
影响因子: 4
作者:
Ismagilov, RF;Stroock, AD;Stone, HA
通讯作者: Stone, HA
DOI: 10.1126/science.283.5400.346
发表时间: 1999-01-15
期刊: SCIENCE
影响因子: 56.9
作者:
Weigl, BH;Yager, P
通讯作者: Yager, P
DOI: 10.1039/c2lc40466d
发表时间: 2012-01-01
期刊: LAB ON A CHIP
影响因子: 6.1
作者:
Nguyen, Transon V.;Duncan, Philip N.;Hui, Elliot E.
通讯作者: Hui, Elliot E.