A multicenter analytical performance evaluation of a multiplexed immunoarray for the simultaneous measurement of biomarkers of micronutrient deficiency, inflammation and malarial antigenemia.
A multicenter analytical performance evaluation of a multiplexed immunoarray for the simultaneous measurement of biomarkers of micronutrient deficiency, inflammation and malarial antigenemia.
复制标题
DOI:
10.1371/journal.pone.0259509
复制
发表时间:
2021
期刊:
影响因子:
3.7
通讯作者:
Boyle DS
中科院分区:
文献类型:
--
作者:
Brindle E;Lillis L;Barney R;Bansil P;Hess SY;Wessells KR;Ouédraogo CT;Arredondo F;Barker MK;Craft NE;Fischer C;Graham JL;Havel PJ;Karakochuk CD;Zhang M;Mussai EX;Mapango C;Randolph JM;Wander K;Pfeiffer CM;Murphy E;Boyle DS
A lack of comparative data across laboratories is often a barrier to the uptake and adoption of new technologies. Furthermore, data generated by different immunoassay methods may be incomparable due to a lack of harmonization. In this multicenter study, we describe validation experiments conducted in a single lab and cross-lab comparisons of assay results to assess the performance characteristics of the Q-plex™ 7-plex Human Micronutrient Array (7-plex), an immunoassay that simultaneously quantifies seven biomarkers associated with micronutrient (MN) deficiencies, inflammation and malarial antigenemia using plasma or serum; alpha-1-acid glycoprotein, C-reactive protein, ferritin, histidine-rich protein 2, retinol binding protein 4, soluble transferrin receptor, and thyroglobulin. Validations included repeated testing (n = 20 separately prepared experiments on 10 assay plates) in a single lab to assess precision and linearity. Seven independent laboratories tested 76 identical heparin plasma samples collected from a cohort of pregnant women in Niger using the same 7-plex assay to assess differences in results across laboratories. In the analytical validation experiments, intra- and inter-assay coefficients of variation were acceptable at <6% and <15% respectively and assay linearity was 96% to 99% with the exception of ferritin, which had marginal performance in some tests. Cross-laboratory comparisons showed generally good agreement between laboratories in all analyte results for the panel of 76 plasma specimens, with Lin’s concordance correlation coefficient values averaging ≥0.8 for all analytes. Excluding plates that would fail routine quality control (QC) standards, the inter-assay variation was acceptable for all analytes except sTfR, which had an average inter-assay coefficient of variation of ≥20%. This initial cross-laboratory study demonstrates that the 7-plex test protocol can be implemented by users with some experience in immunoassay methods, but familiarity with the multiplexed protocol was not essential.
登录
查看更多内容
影响因子:
3.8
作者:
Arndt MB;Cantera JL;Mercer LD;Kalnoky M;White HN;Bizilj G;Boyle DS;de Hostos EL;Choy RKM
通讯作者:
Choy RKM
影响因子:
168.9
作者:
BEADLE, C;LONG, GW;HOFFMAN, SL
通讯作者:
HOFFMAN, SL
影响因子:
2.9
作者:
Salvante, Katrina G.;Brindle, Eleanor;Nepomnaschy, Pablo A.
通讯作者:
Nepomnaschy, Pablo A.
影响因子:
5.9
作者:
Silubonde, Takana Mary;Baumgartner, Jeannine;Norris, Shane
通讯作者:
Norris, Shane
影响因子:
2.2
作者:
Brindle, Eleanor;Fujita, Masako;O'Connor, Kathleen A.
通讯作者:
O'Connor, Kathleen A.