Repeatability of Choroidal Thickness Measurements on Enhanced Depth Imaging Optical Coherence Tomography Using Different Posterior Boundaries.
Repeatability of Choroidal Thickness Measurements on Enhanced Depth Imaging Optical Coherence Tomography Using Different Posterior Boundaries.
复制标题
DOI:
10.1016/j.ajo.2016.06.023
复制
发表时间:
2016-09
影响因子:
4.2
通讯作者:
Yiu G
中科院分区:
文献类型:
--
作者:
Vuong VS;Moisseiev E;Cunefare D;Farsiu S;Moshiri A;Yiu G
To assess the reliability of manual choroidal thickness measurements by comparing different posterior boundary definitions of the choroidal-scleral junction on enhanced depth imaging optical coherence tomography (EDI-OCT). Reliability analysis Two graders marked the choroidal-scleral junction with segmentation software using different posterior boundaries: 1) the outer border of the choroidal vessel lumen, 2) the outer border of the choroid stroma, and 3) the inner border of the sclera, to measure the vascular choroidal thickness (VCT), stromal choroidal thickness (SCT), and total choroidal thickness (TCT), respectively. Measurements were taken at 0.5 mm intervals from 1.5 mm nasal to 1.5 mm temporal to the fovea, and averaged continuously across the central 3 mm of the macula. Intraclass correlation coefficient (ICC) and coefficient of reliability (CR) were compared to assess intergrader and intragrader reliability. Choroidal thickness measurements varied significantly with different posterior boundaries (P = <0.001 for all). Intergrader ICCs were greater for SCT (0.959 – 0.980) than TCT (0.928 – 0.963) and VCT (0.750 – 0.869), even in eyes where choroidal-scleral junction visibility was <75%. Intergrader CRs were lower for SCT (41.40 – 62.31) than TCT (61.13 – 74.24) or VCT (72.44 – 115.11). ICCs and CRs showed greater reliability for averaged VCT, SCT, or TCT measurements, than at individual locations. Intragrader ICCs and CRs were comparable to intergrader values. Choroidal thickness measurements are more reproducible when measured to the border of the choroid stroma (SCT) than the vascular lumen (VCT) or sclera (TCT).
登录
查看更多内容
影响因子:
13.7
作者:
Chung, Song Ee;Kang, Se Woong;Kim, Yun Taek
通讯作者:
Kim, Yun Taek
影响因子:
2
作者:
Chen, Wei;Song, Hui;Chu, Yanhua
通讯作者:
Chu, Yanhua
影响因子:
4.4
作者:
Lin, Phoebe;Mettu, Priyatham S.;Mruthyunjaya, Prithvi
通讯作者:
Mruthyunjaya, Prithvi
影响因子:
8.1
作者:
Adhi, Mehreen;Brewer, Erika;Waheed, Nadia K.;Duker, Jay S.
通讯作者:
Duker, Jay S.
DOI:
10.2147/opth.s53989
发表时间:
2014
期刊:
Clinical ophthalmology (Auckland, N.Z.)
影响因子:
--
作者:
Falcão MS;Gonçalves NM;Freitas-Costa P;Beato JB;Rocha-Sousa A;Carneiro A;Brandão EM;Falcão-Reis FM
通讯作者:
Falcão-Reis FM