Evaluation of the SD Bioline Norovirus rapid immunochromatography test using fecal specimens from Korean gastroenteritis patients.
Evaluation of the SD Bioline Norovirus rapid immunochromatography test using fecal specimens from Korean gastroenteritis patients.
复制标题
DOI:
10.1016/j.jviromet.2012.08.014
复制
发表时间:
2012-12
影响因子:
3.1
通讯作者:
Lee KM
中科院分区:
文献类型:
--
作者:
Kim HS;Hyun J;Kim JS;Song W;Kang HJ;Lee KM
► The new immunochromatography test for norovirus was evaluated. ► This test showed excellence reproducibility, no cross-reactivity and no interference. ► This test showed high agreement rate compared with real-time PCR. ► The assay is a useful tool for rapid screening to identify of norovirus infection. The analytical and clinical performance of a new rapid immunochromatography test, the SD Bioline Norovirus test, was evaluated for the detection of human norovirus in fecal specimens. The analytical performance studies were performed for detection limit, reproducibility, cross-reactivity, and interference. For comparison, 92 norovirus-positive stool samples and 126 norovirus-negative samples for which the results were confirmed by 2 different real-time PCR kits were used. The rapid immunochromatography test detected the equivalent of 4.48 × 106 copies/mL of the norovirus genome in stool samples. On performing the repeatability/reproducibility test, samples above this concentration all provided positive results (100%) and 97.8% of the samples slightly below this concentration (2.45 × 106 copies/mL) provided negative results. No cross-reactivity or interference was detected. Positive percent agreement (sensitivity), negative percent agreement (specificity), and overall percent agreement of the rapid immunochromatography test compared with testing by real-time PCR were 90.2%, 100%, and 95.9%, respectively. In addition, the rapid immunochromatography test was completed within 20 min. The SD Bioline Norovirus test was, therefore, easier and more rapid to perform and showed excellent reproducibility, no cross-reactivity, no interference, and high agreement compared with real-time PCR. Thus, this test is useful for rapid screening to identity norovirus infection.
登录
查看更多内容
影响因子:
4.9
作者:
Park KS;Baek KA;Kim DU;Kwon KS;Bing SH;Park JS;Nam HS;Lee SH;Choi YJ
通讯作者:
Choi YJ
影响因子:
8.8
作者:
Kirby, Andrew;Gurgel, Ricardo Q.;Cuevas, Luis E.
通讯作者:
Cuevas, Luis E.
影响因子:
12.7
作者:
Chung, Ju-Young;Han, Tae-Hee;Hwang, Eung-Soo
通讯作者:
Hwang, Eung-Soo
DOI:
10.1016/j.diagmicrobio.2011.08.023
发表时间:
2011-12-01
影响因子:
2.9
作者:
Monteiro Siqueira, Jones Anderson;Linhares, Alexandre da Costa;Gabbay, Yvone Benchimol
通讯作者:
Gabbay, Yvone Benchimol
影响因子:
3.1
作者:
de Bruin, Erwin;Duizer, Erwin;Koopmans, Marion P. G.
通讯作者:
Koopmans, Marion P. G.