Three-dimensional fusion of pulmonary SPECT and CT images using multimodality devices.
Three-dimensional fusion of pulmonary SPECT and CT images using multimodality devices.
批准号:
10670852
负责人:
MATSUNAGA Naofumi
金额:
$2.18万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
1998
资助国家:
日本
项目状态:
已结题
起止时间:
1998 至 1999
中文摘要
点击翻译按钮获取中文摘要
英文摘要
A phantom study was conducted to evaluate the feasibility of body contour definition using Compton scatter photons from external sources of technotium-99m pertechnotate (Tc-99m) to create a fusion image of CT and SPECT images. External sources from 1 mCi (37MBq) Tc-99m were placed on each collimator, and body-contour SPECT images were obtained using an energy window of 100 kcV±25% for detecting 90°and 180°Compton scatter photons of Tc-99m from the body surface in water-filled cylindrical and hexagonal phantoms, and in a chest phantom with a Tc-99m-avid simulated lung nodule and multimodality surface markers. In the chest phantom, each transaxial SPECT slices was registered with the corresponding CT slice using image-matching soft-ware. A summation of the registered images yielded a three-dimensional (3-D) fusion image of this phantom. This method clearly visualized the body contour on all the SPECT slices in all the phantoms except for the complex hexagonal phantom. There was no signif … More icant difference between known and SPECT-measured diameters of the cylindrical phantom. The fit of CT and SPECT images of the chest phantom was achieved with a mean alignment error of 5% in visual inspection, which was improved to 0.2% after correction of the magnification of the SPECT images according to the resultant dimensional differences. The 3-D fusion image of this phantom effectively visualized the anatomic location of the lung nodule and surface markers. This simple method effectively provided boundary information of the cold phantoms. Although further improvements of the regisration technique with CT images are desirable, the body-contour SPECT images obtained by this method has the potential for accurately creating a 3-D fusion image with CT images, and is a very feasible way anticipating the anatomical localization of a target tissue. In addition to these experimental study, the usefulness of three-dimensional Xenon-133 SPECT imaging in the evaluation of lung ventilation impairments in patients with lung cancer and in the assessment of resection targets for lung volume reduction surgery in patients with pulmonary emphysema were clinically evaluated. The associations between abnormal diaphragm/chest wall motions and regional ventilation in pulmonary emphysema was also evaluated by interstudy comparison of breathing magnetic resonance (MR) imaging and three-dimensional Xenon-133 SPECT. The results showed that this three-dimensional image was useful for the evaluation of abnormal ventilation in patients with lung cancer, and for the detection of resection targets and assessments of therapeutic effects of the reduction surgery in patients with pulmonary emphysema. The correlations between (MR) imaging and three-dimensional Xenon-133 SPECT indicate the close associations between abnormal mobility or coordination of diaphragm/chest wall motions and abnormal ventilation in each hemithorax in patients with pulmonary emphysema. Less
期刊论文(12)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
SUGA K.: "Interactions of regional respiratory mechanics and pulmonary ventilatory impairment in pulmonary emphysema:Assessment with dynamic MRI and Xenon-133SPECT"Chest. 112(in press). (2000)
SUGA K.:“肺气肿中局部呼吸力学与肺通气障碍的相互作用:动态 MRI 和 Xenon-133SPECT 评估”胸部。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
SUGA K: "Interactions of regional respiratory mechanics and pulmonary ventilator impairment in pulmonary emphycema: assessments with dynamic MRI and Xenon-133 SPECT"Chest. 112(in press). (2000)
SUGA K:“肺气肿中局部呼吸力学和肺通气机损伤的相互作用:动态 MRI 和 Xenon-133 SPECT 的评估”胸部。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
SUGA K.: "Evaluation of abnormal regional ventilation in patients with lung cancer using three-dimentional display of dynamic Xenon-133 SPECT"Nuclear Medicine Communication. 19. 593-598 (1998)
SUGA K.:“使用动态Xenon-133 SPECT三维显示评估肺癌患者局部通气异常”核医学交流。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Suga K, et al: "Three-dimensional surface display of dynamic pulmonary Xenon-133 SPECT in patients with obstructive lung disease."journal of Nuclear Medicine. 39. 889-893 (1998)
Suga K 等人:“阻塞性肺病患者动态肺 Xenon-133 SPECT 的三维表面显示。”核医学杂志。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Suga K, et al: "Evaluation of abnormal regional ventilation in patients with lung cancer using three-dimensional display of dynamic xenon-133 SPECT."Nuclear Medicine Communication. 19. 593-598 (1998)
Suga K 等人:“使用动态氙 133 SPECT 三维显示评估肺癌患者局部通气异常。”核医学通讯。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
共 12 条
Clinical efficacy of doronary CT angiography using dual-source CT
-
批准号:23591770
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$3.33万
-
财政年份:2011
-
负责人:MATSUNAGA Naofumi
-
依托单位:
Construction of online electronic teaching file for the education of special radiologist using the MIRC server of Radiological Society of North America
-
批准号:18591348
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.5万
-
财政年份:2006
-
负责人:MATSUNAGA Naofumi
-
依托单位:
Construction of e-textbook for the education of the special radiologist
-
批准号:16591207
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.3万
-
财政年份:2004
-
负责人:MATSUNAGA Naofumi
-
依托单位:
Construction of e-learning for the Radiologists
-
批准号:14570862
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.11万
-
财政年份:2002
-
负责人:MATSUNAGA Naofumi
-
依托单位:
Cine MR Imaging of Aortic Dissection ; Comparison with Spin-echo MR Imaging.
-
批准号:07671006
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.6万
-
财政年份:1995
-
负责人:MATSUNAGA Naofumi
-
依托单位:
Basic and clinical research of Gd-DTPA enhanced MR imaging and analysis of cardiac function in the patients with myocardial infarction
-
批准号:04670672
-
项目类别:Grant-in-Aid for General Scientific Research (C)
-
资助金额:$1.34万
-
财政年份:1992
-
负责人:MATSUNAGA Naofumi
-
依托单位:
国内基金
海外基金
登录
查看更多内容
基于多模态影像和术中滑轨 CT 数据模型优化腹腔镜术区定位
-
批准号:JCZRLH202600599
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:
-
依托单位:
基于高灵敏度PET/CT的碳离子放疗剂量验证与疗效预测研究
-
批准号:JCZRLH202601703
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:
-
依托单位:
人工智能与成像物理机理协同优化的超低剂量光子计数CT成像技术研究
-
批准号:JCZRLH202601895
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:
-
依托单位:
人工智能在非增强CT检测急性缺血性脑卒中的机制研究
-
批准号:JCZRLH202600236
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:
-
依托单位:
基于增强CT/EUS时空环境放射组学及穿刺病理组学联合融合机器学习预测胰腺癌生存及化疗响应
-
批准号:JCZRLH202600233
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:
-
依托单位:
基于人工智能与多组学的III期结核性脓胸CT“低密度线”形成机制及手术时机预测模型研究
-
批准号:JCZRMS202602483
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:
-
依托单位:
基于增强CT影像组学机器学习算法在鉴别胃肠间质瘤KIT外显子11、9突变及PDGFRA 突变的多模态研究
-
批准号:2026JJ82481
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:陈晨
-
依托单位:
基于18F-FAPI-04 PET/CT与增强CT的Suidan评分在卵巢癌减瘤术前评估中的价值比较研究
-
批准号:2026JJ81876
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:戴嘉舜
-
依托单位:
基于深度卷积神经网络的的胸腺CT影像特征挖掘及可解释性胸腺瘤相关重症肌无力诊疗预测模型构建研究
-
批准号:2026JJ50300
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:周昊
-
依托单位:
沙眼衣原体感染入侵新机制:通过T3SS效应蛋白CT622与ARP2相互作用介导宿主细胞质膜重塑
-
批准号:2026JJ50576
-
项目类别:省市级项目
-
资助金额:--
-
批准年份:2026
-
负责人:雷文波
-
依托单位: