High Resolution Detectors for Single Photon Cardiac Imaging
High Resolution Detectors for Single Photon Cardiac Imaging
批准号:
7908907
负责人:
GERALD ENTINE
金额:
$44.0万
依托单位国家:
美国
项目类别:
财政年份:
2008
资助国家:
美国
项目状态:
已结题
起止时间:
2008-09-15 至 2011-06-30
关键词:
AddressAnimal ExperimentationAreaBehaviorBrainBromidesCaliberCaliforniaCardiacCeriumChargeCherry - dietaryCollaborationsCollectionCollimatorCoronary ArteriosclerosisCoupledCouplingData DisplayDiagnosisElectronsElementsEvaluationFamilyFinancial compensationFloodsGamma RaysGoalsGrowthHealthcareHeartHumanImageImaging PhantomsInvestigationIodidesIsotopesKidneyLaboratoriesLanthanumLengthLightLiverLungMalignant NeoplasmsMeasurementMeasuresMedical ImagingMethodsMyocardial IschemiaMyocardial perfusionOpticsOrganOutputPatientsPerformancePhasePhotonsPhysiologyPlayPositioning AttributePositron-Emission TomographyProcessPropertyProstateRadialRadioisotopesReadingResearchResearch PersonnelResolutionRoleSaintsSan FranciscoSkeletal systemSourceSpectrum AnalysisStrokeStrontiumStructureSystemTemperatureTestingThickTimeTissuesTubeUniversitiesbasecold temperaturecommercializationcostdesigndetectorimaging detectorimaging modalityimprovedinstrumentationliver functionluminescencemeltingnervous system disorderoutcome forecastphotomultiplierprototyperesponsesingle photon emission computed tomographystatisticsthallium-doped sodium iodidetooltwo-dimensional
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): High Resolution Detectors for Single Photon Cardiac Imaging Single photon emission computed tomography (SPECT) is a powerful, noninvasive medical imaging modality that mathematically reconstructs the three dimensional distribution of a radionuclide throughout the body of a human patient or a research animal. Typically, the collected data are displayed and evaluated as a set of two-dimensional images through the organ or diseased area under investigation. SPECT allows quantitative study of the function in the investigated region and therefore is an extremely useful tool for understanding organ and tissue physiology including that in the heart. SPECT is very commonly used in identifying as well as localizing coronary artery disease and as many as 90% of all myocardial perfusion studies are now performed using SPECT. Thus, SPECT is playing a critical role in cardiac imaging, providing both diagnosis as well as prognosis. However, there is urgent need for improvement in the instrumentation that is currently used for this imaging modality and expand its capabilities in order to exploit its full potential. At present, the performance of SPECT systems often is limited by the detectors used in these systems. Modern SPECT systems consist of scintillation crystals coupled to photomultiplier tubes as detectors. Important requirements for scintillators used in SPECT applications include high light output and high energy resolution, reasonably fast response and high gamma ray stopping efficiency. Ideally, the scintillator should also be inexpensive, rugged and easy to manufacture. Currently, NaI(Tl) is the detector of choice in SPECT systems and it is relatively inexpensive and its light output is fairly large. However, the poor energy resolution of NaI(Tl) often limits SPECT performance. The energy resolution of NaI:Tl is limited by its relatively poor proportionality. If scintillators with higher energy resolution at typical SPECT energies (~140 keV) were available, the essential process of scatter rejection would improve. Furthermore, dual-isotope imaging, which is a unique property of SPECT, would also become possible if scintillators with high energy resolution became available. The goal of the proposed effort is to investigate a new high resolution detector for SPECT studies. Enhanced scatter rejection can be expected along with possibility of dual isotope imaging. The Phase I project will be aimed at demonstrating the feasibility of the proposed concept, while the Phase II project will be aimed at optimization of the new detector, implementation of the prototype module and detailed performance evaluation.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Low Cost Photon Counting Detector for Synchrotron Applications
-
批准号:7801181
-
项目类别:
-
资助金额:$17.41万
-
财政年份:2010
-
负责人:GERALD ENTINE
-
依托单位:
Simultaneous PET-MR Small Animal Imaging
-
批准号:7906390
-
项目类别:
-
资助金额:$14.94万
-
财政年份:2010
-
负责人:GERALD ENTINE
-
依托单位:
Near Infrared Detector for Advanced Opthamology
-
批准号:7536348
-
项目类别:
-
资助金额:$18.0万
-
财政年份:2008
-
负责人:GERALD ENTINE
-
依托单位:
High Resolution Detectors for Single Photon Cardiac Imaging
-
批准号:7536797
-
项目类别:
-
资助金额:$13.5万
-
财政年份:2008
-
负责人:GERALD ENTINE
-
依托单位:
High Resolution Detectors for Single Photon Cardiac Imaging
-
批准号:7700096
-
项目类别:
-
资助金额:$44.0万
-
财政年份:2008
-
负责人:GERALD ENTINE
-
依托单位:
Solid-State Photosensor for PET
-
批准号:7325545
-
项目类别:
-
资助金额:$10.0万
-
财政年份:2007
-
负责人:GERALD ENTINE
-
依托单位:
HIGH RESOLUTION NUCLEAR CARDIAC IMAGING
-
批准号:7470656
-
项目类别:
-
资助金额:$42.62万
-
财政年份:2007
-
负责人:GERALD ENTINE
-
依托单位:
Position Sensitive Microfluidic Detector
-
批准号:7404768
-
项目类别:
-
资助金额:$10.0万
-
财政年份:2007
-
负责人:GERALD ENTINE
-
依托单位:
HIGH RESOLUTION NUCLEAR CARDIAC IMAGING
-
批准号:7270088
-
项目类别:
-
资助金额:$42.67万
-
财政年份:2007
-
负责人:GERALD ENTINE
-
依托单位:
HIGH RESOLUTION NUCLEAR CARDIAC IMAGING
-
批准号:7050314
-
项目类别:
-
资助金额:$10.0万
-
财政年份:2006
-
负责人:GERALD ENTINE
-
依托单位:
Digital Fluoroscopy for Cardiac Imaging
-
批准号:6930681
-
项目类别:
-
资助金额:$10.0万
-
财政年份:2005
-
负责人:GERALD ENTINE
-
依托单位:
A Fast, High Luminosity Scintillator for PET
-
批准号:7120573
-
项目类别:
-
资助金额:$37.45万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
A Fast, High Luminosity Scintillator for PET
-
批准号:6959642
-
项目类别:
-
资助金额:$35.61万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
High Resolution Imaging Detector for Mammography
-
批准号:6830005
-
项目类别:
-
资助金额:$35.0万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
A Fast, High Luminosity Scintillator for PET
-
批准号:6782274
-
项目类别:
-
资助金额:$10.0万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
High Resolution Imaging Detector for Mammography
-
批准号:7116488
-
项目类别:
-
资助金额:$35.0万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
High Resolution Imaging Detector for Mammography
-
批准号:6951127
-
项目类别:
-
资助金额:$35.0万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
A Fast, High Luminosity Scintillator for PET
-
批准号:7277231
-
项目类别:
-
资助金额:$36.22万
-
财政年份:2004
-
负责人:GERALD ENTINE
-
依托单位:
Novel Detector for Small Animal SPECT Imaging
-
批准号:6479290
-
项目类别:
-
资助金额:$10.65万
-
财政年份:2002
-
负责人:GERALD ENTINE
-
依托单位:
In Vivo Molecular Imaging of Cancer in Small Animals
-
批准号:7271182
-
项目类别:
-
资助金额:$27.49万
-
财政年份:2002
-
负责人:GERALD ENTINE
-
依托单位:
海外基金