Automatic and reproducible positioning of phase-contrast MRI for the quantification of global cerebral blood flow.

Automatic and reproducible positioning of phase-contrast MRI for the quantification of global cerebral blood flow.
复制标题

DOI:
10.1371/journal.pone.0095721
复制
发表时间:
2014
期刊:
影响因子:
3.7
通讯作者:
Cao Y
Cao Y
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Liu P;Lu H;Filbey FM;Pinkham AE;McAdams CJ;Adinoff B;Daliparthi V;Cao Y

文献摘要

参考文献

被引文献

相似文献

Phase-Contrast MRI (PC-MRI) is a noninvasive technique to measure blood flow. In particular, global but highly quantitative cerebral blood flow (CBF) measurement using PC-MRI complements several other CBF mapping methods such as arterial spin labeling and dynamic susceptibility contrast MRI by providing a calibration factor. The ability to estimate blood supply in physiological units also lays a foundation for assessment of brain metabolic rate. However, a major obstacle before wider applications of this method is that the slice positioning of the scan, ideally placed perpendicular to the feeding arteries, requires considerable expertise and can present a burden to the operator. In the present work, we proposed that the majority of PC-MRI scans can be positioned using an automatic algorithm, leaving only a small fraction of arteries requiring manual positioning. We implemented and evaluated an algorithm for this purpose based on feature extraction of a survey angiogram, which is of minimal operator dependence. In a comparative test-retest study with 7 subjects, the blood flow measurement using this algorithm showed an inter-session coefficient of variation (CoV) of . The Bland-Altman method showed that the automatic method differs from the manual method by between and , for of the CBF measurements. This is comparable to the variance in CBF measurement using manually-positioned PC MRI alone. In a further application of this algorithm to 157 consecutive subjects from typical clinical cohorts, the algorithm provided successful positioning in 89.7% of the arteries. In 79.6% of the subjects, all four arteries could be planned using the algorithm. Chi-square tests of independence showed that the success rate was not dependent on the age or gender, but the patients showed a trend of lower success rate (p = 0.14) compared to healthy controls. In conclusion, this automatic positioning algorithm could improve the application of PC-MRI in CBF quantification.
DOI: 10.1016/j.neuroimage.2009.07.068
发表时间: 2010-01-01
期刊: NEUROIMAGE
影响因子: 5.7
作者:
Petersen, Esben Thade;Mouridsen, Kim;Golay, Xavier
通讯作者: Golay, Xavier
DOI: 10.1038/sj.jcbfm.9600526
发表时间: 2008-02-01
影响因子: 6.3
作者:
Vernooij, Meike W.;van der Lugt, Aad;Breteler, Monique M. B.
通讯作者: Breteler, Monique M. B.
DOI: 10.1002/mrm.21994
发表时间: 2009-07
影响因子: 3.3
作者:
Xu, Feng;Ge, Yulin;Lu, Hanzhang
通讯作者: Lu, Hanzhang
DOI: 10.1097/00004424-199302000-00004
发表时间: 1993-02-01
影响因子: 6.7
作者:
EVANS, AJ;IWAI, F;PELC, NJ
通讯作者: PELC, NJ
DOI: 10.1038/jcbfm.2008.62
发表时间: 2008-10-01
影响因子: 6.3
作者:
Poels, Marielle M. F.;Ikram, Mohammad Arfan;Breteler, Monique M. B.
通讯作者: Breteler, Monique M. B.