关键词:

项目摘要

项目成果

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Modern characterization of inorganic compounds and metal complexes requires the recording of accurate high-resolution mass spectra. These spectra are not only used to prove the identity of compounds, but also for the elucidation of reaction mechanisms and pathways. They furthermore enable a precise synthesis planning and allow metabolic studies of potential inorganic therapeutics. In accordance with the utilization concept for mass spectrometry of the faculty of Chemistry and Pharmacy, routine mass spectra are recorded in one of the service units of the faculty. The service unit in the Institute of Inorganic and Analytical Chemistry is specialized in the characterization of inorganic compounds such as metal complexes, and their ligands. The broad spectrum of sample types imposes high standards on the requested instrument: potential analytes range from small low-molecular compounds to coordination complexes with biomolecule-based ligands. Therefore, a combination of tandem mass spectrometry with the possibility of an upstream chromatographic separation with simultaneous recording of absorbance spectra by a diode-array detector (DAD) is required. Particularly in the context of bioinorganic samples, a chromatographic separation of complex sample mixtures facilitates metabolism studies or allows to reduce the salt load. The UV/vis activity of many biomolecules further enables a correlation of the signals in the absorbance spectra (recorded by the DAD) and the respective mass spectra, allowing to draw conclusions regarding the association of complex and biomolecule. For the detection of intact adducts, a mild non-fragmenting ionization is required, as interactions with complexes and metal ions can be weak. Hence, the requested instrument should be equipped with electrospray ionization and should be capable of optionally applying a cryospray source, allowing the characterization of highly thermo-labile adducts. To enable a wide scope of applications, the instrument should provide APCI as an alternative ionization source, allowing to deal with low-polarity analytes (APCI, atmospheric pressure chemical ionization).
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
国内基金
海外基金
基于CMC/UPLC-Q-TOF/MS的复骨健步丸活性成分筛选及其活性验证
基于连续晶体的亚毫米级空间分辨率ToF-PET探测器关键技术研究
  • 批准号:
    JCZRMS202600358
  • 项目类别:
    省市级项目
  • 资助金额:
    --
  • 批准年份:
    2026
  • 负责人:
  • 依托单位:
基于PVA纤维捕集-SP-ICP-TOF的深穿透土壤纳米颗粒矿致异常识别方法研究
基于 UPLC-Q-TOF-MS/MS 分析的 异功散活性成分评价及提取工艺研究
  • 批准号:
  • 项目类别:
    省市级项目
  • 资助金额:
    --
  • 批准年份:
    2025
  • 负责人:
    魏江平
  • 依托单位: