Development of a three-dimensional CT simulator and its clinical application

Development of a three-dimensional CT simulator and its clinical application
三维CT模拟器的研制及其临床应用
批准号:
08457243
负责人:
NAGATA Yasushi
金额:
$4.22万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (B)
财政年份:
1996
资助国家:
日本
项目状态:
已结题
起止时间:
1996 至 1997

项目摘要

项目成果

NAGATA Yasushi的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
In 1996, a new helical CT scanner was added to our CT simulator system. This CT scanner facilitates not only rapid CT scanning by the conventional parallel scanning method but also helical and continuous scanning. However, the accuracy of the reconstructed helical CT image for radiotherapy treatment planning (RTP) is not established. The usefulness and limitations of reconstructed helical CT images were demonstrated using an acryl phantom.A conical phantom measuring 100-mm in diameter was specially constructed using acryl. For identification of marginal distortion in the reconstructed CT image, the conical phantom was scanned using 5 mm and 10 mm collimation with 5 or 10mm/sec table speed for 1 sec/rotation with scanning parameters of 120 kVp and 50 mA.Image reconstruction was performed with both the 180-degree compensation algorithm (SHI algorithm) and the 360-degree compensation algorithm (SFI algorithm). The CT window and level was fixed at 200 Hounsfield units (HU), and 120 HU,resp … More ectively. A column phantom was also used for measuring the gradient in the CT number at the marginal surface of different materials. In the study of a conical phantom, the distorsion (D) was measured as a difference netween a larger radius (R) and a smaller radius (r) scanned at the level of 100 mm in radius. In the study of a column phantom, the CT number of each CT slice was measured at every 1 mm intervals.As a result, the reconstructed shape of the margin was competely round when the conical phantom was scanned by the routine conventional CT method. However, distortion appeared when it was reconstructed from helical CT scans. The maximal distortion at a eadius of 100 mm was 2 mm when the phantom was scanned at 5 mm or 10 mm collimation thickness and 10 mm/sec table speed and reconstructed with the SHI algorithm. However, the distortion was below the limits of detection when the phantom was scanned at 5 mm or 10 mm collimation thickness and 5 mm/sec table speed and reconstructed with the SFI algorithm. The gradient of the change in the CT number was larger at the boundary between the acryl and air than at the boundary between the acryl and water. The gradient was also larger at the 5 mm thickness than 10 mm thickness, and at 5 mm/sec table speed than at 10 mm/sec table speed.In conclusion, helical CT parameters should be set up very cautiously for radiotherapy treatment planning because they are subject to image distortion and CT number changes.On the other hand, a network was developed netween the CT simulator and a treatment planning machine. The three-dimensional treatment planning can be possible for clinical application. The clinical significance of the helical CT simulator will be evaluated. Less
期刊论文(26)
专著(0)
科研奖励(0)
会议论文
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
光森通英,永田 靖,他: "放射線治療外来用にデジタルカメラシステムと統合された画像データベースの開発" 日本放射線腫瘍学会誌. 8. 151-159 (1996)
Michihide Mitsumori、Yasushi Nagata 等人:“与门诊放射治疗数码相机系统集成的图像数据库的开发”日本放射肿瘤学会杂志 8. 151-159 (1996)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Nagata,Y., Yamamoto,M., Kokubo,M.et al.: "Development of a Helical CT Simulator : An Experimental Study." Radiology. 205(P). 435 (1997)
Nagata,Y.、Yamamoto,M.、Kokubo,M.等人:“螺旋 CT 模拟器的开发:实验研究”。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Sasai, K, Murata, R, Hiraoka, Y.et.al.: "Radiation theraphy for ocular choroidal neovascularization (Phase I/II study) : preliminary report." Int.J.Radiat.Oncol.Biol.Phys.
Sasai, K、Murata, R、Hiraoka, Y.et.al.:“眼部脉络膜新生血管的放射治疗(I/II 期研究):初步报告。”
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
24
    Extensive research of Taguchi method
    • 批准号:
      15K00056
    • 项目类别:
      Grant-in-Aid for Scientific Research (C)
    • 资助金额:
      $2.58万
    • 财政年份:
      2015
    • 负责人:
      NAGATA Yasushi
    • 依托单位:
    Development of a new Stereotactic Body Radiation Therapy (SBRT) and Intensity Modulated Radiation therapy (IMRT) technique using an integrated Image Guide Radiation Therapy (IGRT) system
    • 批准号:
      22390235
    • 项目类别:
      Grant-in-Aid for Scientific Research (B)
    • 资助金额:
      $6.41万
    • 财政年份:
      2010
    • 负责人:
      NAGATA Yasushi
    • 依托单位:
    International Comparative Research on Asian Modern and Contemporary Theatres
    • 批准号:
      22320035
    • 项目类别:
      Grant-in-Aid for Scientific Research (B)
    • 资助金额:
      $11.4万
    • 财政年份:
      2010
    • 负责人:
      NAGATA Yasushi
    • 依托单位:
    Some Aspects of Japanese & Korean Theatre in Russian & Soviet Federation : its effects and developments
    • 批准号:
      19520100
    • 项目类别:
      Grant-in-Aid for Scientific Research (C)
    • 资助金额:
      $2.75万
    • 财政年份:
      2007
    • 负责人:
      NAGATA Yasushi
    • 依托单位:
    海外基金