LIPID SUPPRESSION USING SELECTIVE INVERSION RECOVERY FOR 3D SPECTROSCOPIC IMG
LIPID SUPPRESSION USING SELECTIVE INVERSION RECOVERY FOR 3D SPECTROSCOPIC IMG
批准号:
7358748
负责人:
MENG GU
金额:
$1.25万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2006
资助国家:
美国
项目状态:
已结题
起止时间:
2006-06-01 至 2007-05-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. INTRODUCTION The most common approach for reducing lipid signals in H brain chemical shift imaging (CSI) is the use of volume preselection via the PRESS technique. [1] This technique produces high quality metabolite spectra within a restricted brain volume. To achieve whole brain coverage, non-selective inversion recovery (IR) techniques are generally applied. [2] [3] At 1.5T, metabolite signal loss from IR is on the order of 30-40%. However, at higher fields, e.g. 3T, the increase in spectral separation between lipids and metabolites allows a frequency selective inversion. This paper discusses the design, implementation and results of an IR CSI pulse sequence that performs selective inversion for lipid suppression. METHOD The chemical shift between lipids and the closest metabolite (NAA) is 0.7 ppm. At 3T, these two spins are separated by 89 Hz. The design goals of the inversion pulse were a transition band less than 89 Hz, an inversion band wide enough to cover all of the lipid signals and a short enough pulse width to neglect relaxation effects during excitation. In the design, we chose a minimum phase RF pulse for a sharp transition band with 500 Hz inversion bandwidth and 20ms pulse width. The RF pulse synthesis was done using the Shinnar-Le Roux algorithm [4]. The ripple amplitudes were chosen such that the transition bandwidth was less than 89Hz. To test the effects of the selective IR, a 3T CSI imaging sequence was implemented with the following characteristics: spectral-spatial spin echo pulse for metabolite excitation and water suppression, TR/TI/TE=2000/170/144 ms, spiral readout gradients, single slice, 2.5 cc voxels and 2 minute acquisition. [5] CONCLUSION We have designed and implemented a 3T frequency selective IR spiral CSI pulse sequence. The effectiveness of the selective inversion recovery is demonstrated on an in vivo scan showing a lipid suppression factor on the order of 10 while maintaining excellent quality metabolite spectra. ACKNOWLEDGEMENTS Lucas foundation, NIH grants RR 09748, CA 48269 REFERENCES [1] P.A. Bottomley, Ann N Y Acad Sci, 508, 333, 333-348, 1987 [2] A. Ebel, et al, MRM, 49, 903-908, 2003 [3] D. M. Spielman, et al., JMRM 2:253-262, 1992 [4] J. Pauly, et al., IEEE Trans. Med. Imaging 10, 53-65, 1991 [5] E. Adalsteinsson, et al., MRM, 39, 889-898, 1998
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
WATER AND LIPID SUPPRESSION USING FREQUENCY-SELECTIVE RF PULSES FOR 1H MRSI
-
批准号:8169861
-
项目类别:
-
资助金额:$1.23万
-
财政年份:2010
-
负责人:MENG GU
-
依托单位:
PARALLEL MRSI RECON WITH ARBITRARY TRAJECTORIES USING K-SPACE SPARSE MATRICES
-
批准号:8169839
-
项目类别:
-
资助金额:$1.23万
-
财政年份:2010
-
负责人:MENG GU
-
依托单位:
HIGH SPEED VOLUMETRIC MRSI WITH ECHO PLANAR K-SPACE TRAJECTORIES
-
批准号:8169891
-
项目类别:
-
资助金额:$0.62万
-
财政年份:2010
-
负责人:MENG GU
-
依托单位:
SIMULTANEOUS QUANTIFICATION OF GLUTAMATE AND GLUTAMINE USING CT-PRESS AT 3T
-
批准号:8169892
-
项目类别:
-
资助金额:$0.93万
-
财政年份:2010
-
负责人:MENG GU
-
依托单位:
SIMULTANEOUS QUANTIFICATION OF GLUTAMATE AND GLUTAMINE USING CT-PRESS AT 3T
-
批准号:7955418
-
项目类别:
-
资助金额:$0.9万
-
财政年份:2009
-
负责人:MENG GU
-
依托单位:
PARALLEL MRSI RECON WITH ARBITRARY TRAJECTORIES USING K-SPACE SPARSE MATRICES
-
批准号:7955365
-
项目类别:
-
资助金额:$1.2万
-
财政年份:2009
-
负责人:MENG GU
-
依托单位:
HIGH SPEED VOLUMETRIC MRSI WITH ECHO PLANAR K-SPACE TRAJECTORIES
-
批准号:7955417
-
项目类别:
-
资助金额:$0.6万
-
财政年份:2009
-
负责人:MENG GU
-
依托单位:
WATER AND LIPID SUPPRESSION USING FREQUENCY-SELECTIVE RF PULSES FOR 1H MRSI
-
批准号:7955387
-
项目类别:
-
资助金额:$1.2万
-
财政年份:2009
-
负责人:MENG GU
-
依托单位:
REPRODUCIBILITY STUDY OF WHOLE-BRAIN SPECTRO IMAG WITH AUTOMATED QUANTIFICATION
-
批准号:7722887
-
项目类别:
-
资助金额:$1.12万
-
财政年份:2008
-
负责人:MENG GU
-
依托单位:
WATER AND LIPID SUPPRESSION USING FREQUENCY-SELECTIVE RF PULSES FOR 1H MRSI
-
批准号:7722934
-
项目类别:
-
资助金额:$1.12万
-
财政年份:2008
-
负责人:MENG GU
-
依托单位:
PARALLEL MRSI RECON WITH ARBITRARY TRAJECTORIES USING K-SPACE SPARSE MATRICES
-
批准号:7722889
-
项目类别:
-
资助金额:$1.12万
-
财政年份:2008
-
负责人:MENG GU
-
依托单位:
LIPID SUPPRESSION USING SELECTIVE INVERSION RECOVERY FOR 3D SPECTROSCOPIC IMG
-
批准号:7601872
-
项目类别:
-
资助金额:$1.73万
-
财政年份:2007
-
负责人:MENG GU
-
依托单位:
QUANTITATIVE 3D BRAIN MRSI WITH PHASED ARRAY ACQUISITION
-
批准号:7358766
-
项目类别:
-
资助金额:$0.94万
-
财政年份:2006
-
负责人:MENG GU
-
依托单位:
ROBUST LIPID SUPPRESSION USING MULTIPLE FREQUENCY PULSES FOR BRAIN MRS AT 3T
-
批准号:7358774
-
项目类别:
-
资助金额:$0.94万
-
财政年份:2006
-
负责人:MENG GU
-
依托单位:
LIPID SUPPRESSION USING SELECTIVE INVERSION RECOVERY FOR 3D SPECTROSCOPIC IMAGIN
-
批准号:6978392
-
项目类别:
-
资助金额:$1.0万
-
财政年份:2004
-
负责人:MENG GU
-
依托单位:
海外基金