课题基金 / 基金详情

CEREBRAL BLOOD VOLUME MAPPING IN HUMANS AT 7T WITH HYPEROXIC CONTRAST

CEREBRAL BLOOD VOLUME MAPPING IN HUMANS AT 7T WITH HYPEROXIC CONTRAST
高氧对比 7T 下人类脑血容量图
批准号:
8361981
负责人:
David Pilkinton
金额:
$2.31万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2011
资助国家:
美国
项目状态:
已结题
起止时间:
2011-06-01 至 2012-05-31

项目摘要

项目成果

David Pilkinton的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. Primary support for the subproject and the subproject's principal investigator may have been provided by other sources, including other NIH sources. The Total Cost listed for the subproject likely represents the estimated amount of Center infrastructure utilized by the subproject, not direct funding provided by the NCRR grant to the subproject or subproject staff. Increasing the inspired fraction of oxygen (FiO2>0.21) has been shown in numerous studies to produce positive contrast enhancement in T2*-weighted images based on the blood oxygenation-dependent (BOLD) effect. Recently, it has been shown that cerebral blood volume (CBV) can be accurately calculated by measuring signal changes in EPI at 3T during short epochs (<6min) of mild hyperoxia. Typically, images acquired in this fashion have low spatial resolution (approximately 4x4x6mm) because of the need for: (a) high contrast-to-noise ratio (CNR), since tissue signal changes are typically small, and (b) high temporal resolution to average the signal fluctuations inherent to heavily T2*-weighted EPI. Ultra-high field strengths (>7T) can enhance the CNR of this experiment due to the nonlinear increase in BOLD contrast with field strength, potentially allowing for significantly increased spatial resolution. However, performing a high- resolution CBV experiment using EPI is difficult at 7T for a number of reasons. Geometric distortions and signal dropout due to B0 inhomogeneity near air-tissue interfaces are substantial problems at 7T. Even more significantly, quantifying CBV with this method requires that the BOLD contrast be primarily intravascular. Since venous blood at 7T has a T2*<10ms, a short echo time (TE<9 ms) and readout length are required that are less than standard EPI sequences can produce even at high bandwidth and with partial-Fourier (PF) encoding. Furthermore, acquiring thin slices using a 2D approach is difficult to do due to slice profile imperfections. To address these problems, we are investigating the use of high resolution (1x1x2mm) steady-state acquisition partial-Fourier encoded segmented 3D EPI for hyperoxia-based CBV maps at 7T.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
MEASUREMENT OF CEREBRAL OXIDATIVE METABOLISM WITH SIMULTANEOUS MRI AND DOS
  • 批准号:
    8362015
  • 项目类别:
  • 资助金额:
    $0.77万
  • 财政年份:
    2011
  • 负责人:
    David Pilkinton
  • 依托单位:
QUANTITATIVE SODIUM MRI AT 7T WITH 12 CHANNEL PHASED-ARRAY COIL
  • 批准号:
    8361983
  • 项目类别:
  • 资助金额:
    $1.54万
  • 财政年份:
    2011
  • 负责人:
    David Pilkinton
  • 依托单位:
ABSOLUTE CEREBRAL BLOOD FLOW QUANTIFICATION WITH ASL DURING HYPEROXIA
  • 批准号:
    8362014
  • 项目类别:
  • 资助金额:
    $0.77万
  • 财政年份:
    2011
  • 负责人:
    David Pilkinton
  • 依托单位:
MEASUREMENT OF CBF AND CBV IN HUMANS USING WASHOUT OF HYPEROXIC CONTRAST
  • 批准号:
    8361982
  • 项目类别:
  • 资助金额:
    $2.31万
  • 财政年份:
    2011
  • 负责人:
    David Pilkinton
  • 依托单位:
国内基金
海外基金
湍流和化学交互作用对H2-Air-H2O微混燃烧中NO生成的影响研究
  • 批准号:
    51976048
  • 项目类别:
    面上项目
  • 资助金额:
    61.0万元
  • 批准年份:
    2019
  • 负责人:
    邱朋华
  • 依托单位: