Multi Source E-Beam kV X-Ray Tube for Image-Guided Radiotheraphy
Multi Source E-Beam kV X-Ray Tube for Image-Guided Radiotheraphy
批准号:
9266745
负责人:
DOUGLAS P BOYD
金额:
$52.69万
依托单位国家:
美国
项目类别:
财政年份:
2015
资助国家:
美国
项目状态:
已结题
起止时间:
2015-04-01 至 2018-05-31
关键词:
AbdomenBreathingCharacteristicsChestClinicalCollimatorColon CarcinomaDoseElectron BeamEligibility DeterminationEnsureEvaluationExposure toEyeFundingFutureGeometryHealthImageIndustryLettersLinear Accelerator Radiotherapy SystemsLung NeoplasmsMalignant - descriptorMalignant neoplasm of lungMalignant neoplasm of prostateMotionNormal tissue morphologyOncologistOperative Surgical ProceduresPatientsPerformancePeriodicityPhasePhysiologic pulsePlant LeavesPositioning AttributePower SourcesPriceProductionRadiationRadiation exposureRadiation therapyRectal CancerReportingResearchResolutionRoentgen RaysSafetyScanningScienceScientistSeriesSideSourceSpottingsStructureSurfaceSystemTestingTimeToxic effectTubeTungstenUpdateVendorWorkauthoritycancer imagingclinical practicecone-beam computed tomographycontrast imagingdesigndigitalimage guidedimage guided radiation therapyimaging systemimprovedlung imagingmalignant breast neoplasmnew technologynovelprototypepublic health relevancetemporal measurementtomosynthesistreatment planningtumorvoltage
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): This project will develop a commercial product that will enable for the first time realtime tumor tracking during radiotherapy at an attractive price point and with minimal interference with standard clinical practice. The key novel technology is an optimized multi-source X-ray tube with 19 focal spots that is placed below the multi-leaf collimator (MLC) of a radiotherapy system as shown below. By steering a focused electron beam (e-beam) on a series of 19 cooled tungsten targets in sequence, this system will provide a set of projection images that can be reconstructed into a 20 cm × 20 cm × 20 cm digital tomosynthesis (DTS) volume image that surrounds the radiation target. The projection X-rays are captured by a universal kV-MV imager that can record portal MV images interlaced with the sequence of tomographic kV images. Since the sources are positioned around the perimeter of the MLC, the resulting tomographic cross section images are aligned perpendicular to the axis of the therapy beam. This geometry is referred to as "Beam's Eye View" imaging. The DTS images will be used to provide precise reference coordinates of a tumor surface for programming of the MLC, in near real-time. The preliminary specifications for the system indicate that a repetition rate of 2-3 volume images per second with near 1 mm spatial resolution will be possible. The multi-source e-beam X-ray tube will be developed by substantially the same premier team who developed the original Imatron EBCT scanners and the more recent e-beam luggage scanner. The e-beam team consisting of TeleSecurity Sciences, Inc. scientists, consultants, and vendors has partnered with the premier cone beam CT team at UC Davis along with a key Varian consultant, who are authorities on flat panel X-ray imagers, and in particular the Side-view of the TumoTrakTM in a Truebeam gantry kV-MV imager that will be used in this project to provide simultaneous MV portal imaging with interlaced kV DTS imaging of the tumor position. Phase 1 of the project extended the preliminary work to more precisely define the final design specifications for a future commercial system that will be appropriate for the entire radiotherapy industry. Phase 2 funding will develop a suitable prototype of the multi-source eBeam X-ray tube which will demonstrate the feasibility and performance of the commercial system. The majority of radiotherapy vendors have provided guidance and letters of support for this project. The commercial implementation of the proposed system in future radiotherapy systems will permit treatment plans that will have far improved localization of radiation exposure within reduced margins beyond the apparent boundaries of a malignant mass with a corresponding reduction in exposure to surrounding normal structures. This will be especially important in treating tumors of the chest and upper abdomen during free breathing where periodic motion in the range of 2 cm to 5 cm is often encountered.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Multi Source E-Beam kV X-Ray Tube for Image-Guided Radiotheraphy
-
批准号:9750326
-
项目类别:
-
资助金额:$21.82万
-
财政年份:2015
-
负责人:DOUGLAS P BOYD
-
依托单位:
Multi-Source E-Beam kV X-Ray Tube for Image-Guided Radiotherapy
-
批准号:8832656
-
项目类别:
-
资助金额:$29.95万
-
财政年份:2015
-
负责人:DOUGLAS P BOYD
-
依托单位:
Multi Source E-Beam kV X-Ray Tube for Image-Guided Radiotheraphy
-
批准号:9138890
-
项目类别:
-
资助金额:$125.49万
-
财政年份:2015
-
负责人:DOUGLAS P BOYD
-
依托单位:
A HIGH-SPEED DPA SCANNER FOR DIAGNOSIS OF OSTEOPOROSIS
-
批准号:2079195
-
项目类别:
-
资助金额:$30.69万
-
财政年份:1987
-
负责人:DOUGLAS P BOYD
-
依托单位:
HIGH-SPEED OPA SCANNER FOR DIAGNOSIS OF OSTEOPOROSIS
-
批准号:3490248
-
项目类别:
-
资助金额:$5.0万
-
财政年份:1987
-
负责人:DOUGLAS P BOYD
-
依托单位:
A HIGH-SPEED DPA SCANNER FOR DIAGNOSIS OF OSTEOPOROSIS
-
批准号:2079196
-
项目类别:
-
资助金额:$19.31万
-
财政年份:1987
-
负责人:DOUGLAS P BOYD
-
依托单位:
海外基金