Exploring a promising design for the next generation time-of-flight PET detector
Exploring a promising design for the next generation time-of-flight PET detector
批准号:
9918874
负责人:
CRAIG S LEVIN
金额:
$51.89万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2017
资助国家:
美国
项目状态:
已结题
起止时间:
2017-06-01 至 2022-05-31
关键词:
3-DimensionalClinicClinicalCollectionCommunitiesCompton radiationCoupledCrystallizationDataDetectionDigital Signal ProcessingDimensionsDoseElectronicsElementsEventFaceFutureGoalsHot SpotImageImage EnhancementImaging PhantomsIncidenceLesionLightLocationLutetiumMeasurementMeasuresMethodsNoiseOpticsOutputPatientsPerformancePhotonsPositioning AttributePositron-Emission TomographyProcessProductionRadiation Dose UnitRecoveryResearchResolutionScanningSideSignal TransductionSiliconSystemTechniquesTechnologyTimeTissuesTracerVariantVisualizationWidthabsorptionanalogattenuationbasecancer imagingcost effectivedata acquisitiondesigndetectorexperimental studyimage reconstructionimaging studyimprovedinnovationkinematicsnext generationnovelphotomultiplierphoton-counting detectorpreservationprototyperesponsescale upstatisticstomographytumor molecular fingerprintuptake
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Project Summary/Abstract
We propose to study a promising candidate for the next generation time-of-flight (TOF)-positron emission
tomography (PET) annihilation photon detector. By enabling significant increases in the reconstructed
image signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), TOF-PET has demonstrated
substantial clinical impact on the visualization and quantification of molecular signatures of cancer in
patients. In particular it has been shown to improve image quality and accuracy in count starved and
contrast limited lesion detection scenarios. The effective photon sensitivity boost provided by TOF can
also be exploited to significantly reduce injected dose to the patient and/or study duration, factors that
would make PET more practical, cost-effective, and safe for a variety of clinical cancer imaging
applications. Thus, studies that further advance the TOF-PET technique, and photon sensitivity in
general, are highly worthwhile. The key to better TOF-PET performance is to improve the annihilation
photon pair coincidence time resolution (CTR) measured between any two detection elements in the
system, which has been a focus of research for the past two decades. Current commercially available
PET systems achieve a CTR of roughly 350 to 800 ps full-width-at-half-maximum (FWHM). A goal of this
proposal is to employ a novel scintillation detection configuration in order to achieve 100 ps FWHM CTR,
without compromising other important performance parameters. This novel configuration also enables
another capability not possible with the conventional PET detector: The ability to measure the energy and
three-dimensional (3D) position of one or more annihilation photon interactions in the detector. Owing to
the fact that most incoming 511 keV photons undergo inter-crystal Compton scatter in the detectors, we
can exploit the kinematics of that process to estimate the photon angle-of-incidence. If successful, that
capability enables us to accurately position the first interaction of such multi-crystal events, but also offers
the potential to retain a high fraction of photon events that are normally rejected by a conventional PET
system, such as single (unpaired) photons, random coincidences, tissue-scatter coincidences, and
multiple (>2) photon coincidences. Since these normally-discarded events are over 10-fold more
probable than true coincidence events in a standard PET study, this 3D position sensitive detector shows
promise as another method to greatly boost photon sensitivity. If successful, this resulting substantial
photon sensitivity increase, along with the substantial image SNR enhancement possible with 100 ps
CTR would enable PET to be more sensitive, accurate, and practical for cancer imaging. In this project
we will design and develop these next-generation detectors, integrate these modules into a prototype
partial-ring PET system, and compare image quality and accuracy available with this partial-ring system
to a state-of-the-art whole body TOF-PET system currently installed in our imaging clinic.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Exploring concepts in nanophotonics and metamaterials to create a 'super-scintillator' for time-of-flight positron emission tomography
-
批准号:10509318
-
项目类别:
-
资助金额:$23.61万
-
财政年份:2022
-
负责人:CRAIG S LEVIN
-
依托单位:
Translation and Validation of a Radiofrequency-Penetrable PET insert for Simultaneous PET/MRI imaging of Neurological Disorders
-
批准号:10616704
-
项目类别:
-
资助金额:$58.87万
-
财政年份:2022
-
负责人:CRAIG S LEVIN
-
依托单位:
Exploring concepts in nanophotonics and metamaterials to create a 'super-scintillator' for time-of-flight positron emission tomography
-
批准号:10685592
-
项目类别:
-
资助金额:$19.68万
-
财政年份:2022
-
负责人:CRAIG S LEVIN
-
依托单位:
Translation and Validation of a Radiofrequency-Penetrable PET insert for Simultaneous PET/MRI imaging of Neurological Disorders
-
批准号:10365492
-
项目类别:
-
资助金额:$61.79万
-
财政年份:2022
-
负责人:CRAIG S LEVIN
-
依托单位:
RF-penetrable PET ring for acquiring simultaneous time-of-flight PET and MRI data
-
批准号:10268119
-
项目类别:
-
资助金额:$15.77万
-
财政年份:2020
-
负责人:CRAIG S LEVIN
-
依托单位:
Technologies to drastically boost photon sensitivity for brain-dedicated PET
-
批准号:9420111
-
项目类别:
-
资助金额:$41.57万
-
财政年份:2017
-
负责人:CRAIG S LEVIN
-
依托单位:
A new direction to achieve ultra-fast timing for positron emission tomography
-
批准号:9444922
-
项目类别:
-
资助金额:$64.71万
-
财政年份:2017
-
负责人:CRAIG S LEVIN
-
依托单位:
Exploring a promising design for the next generation time-of-flight PET detector
-
批准号:10171564
-
项目类别:
-
资助金额:$51.63万
-
财政年份:2017
-
负责人:CRAIG S LEVIN
-
依托单位:
Technologies to drastically boost photon sensitivity for brain-dedicated PET
-
批准号:9568754
-
项目类别:
-
资助金额:$41.09万
-
财政年份:2017
-
负责人:CRAIG S LEVIN
-
依托单位:
Stanford Molecular Imaging Scholars (SMIS) Program
-
批准号:10410895
-
项目类别:
-
资助金额:$22.08万
-
财政年份:2016
-
负责人:CRAIG S LEVIN
-
依托单位:
Stanford Molecular Imaging Scholars (SMIS) Program
-
批准号:10649567
-
项目类别:
-
资助金额:$55.9万
-
财政年份:2016
-
负责人:CRAIG S LEVIN
-
依托单位:
Stanford Molecular Imaging Scholars (SMIS)
-
批准号:9440617
-
项目类别:
-
资助金额:$0.15万
-
财政年份:2016
-
负责人:CRAIG S LEVIN
-
依托单位:
Stanford Molecular Imaging Scholars (SMIS)
-
批准号:9321966
-
项目类别:
-
资助金额:$39.11万
-
财政年份:2016
-
负责人:CRAIG S LEVIN
-
依托单位:
RF-penetrable PET ring for acquiring simultaneous time-of-flight PET and MRI data
-
批准号:9068914
-
项目类别:
-
资助金额:$59.68万
-
财政年份:2015
-
负责人:CRAIG S LEVIN
-
依托单位:
IEEE Medical Imaging Conference Trainee Support
-
批准号:8529864
-
项目类别:
-
资助金额:$1.0万
-
财政年份:2013
-
负责人:CRAIG S LEVIN
-
依托单位:
Probing optical property changes in photonic materials for faster timing in PET
-
批准号:8634777
-
项目类别:
-
资助金额:$18.0万
-
财政年份:2013
-
负责人:CRAIG S LEVIN
-
依托单位:
Probing optical property changes in photonic materials for faster timing in PET
-
批准号:8512084
-
项目类别:
-
资助金额:$22.04万
-
财政年份:2013
-
负责人:CRAIG S LEVIN
-
依托单位:
Photon interaction depth encoded time-of-flight PET
-
批准号:8385011
-
项目类别:
-
资助金额:$22.85万
-
财政年份:2012
-
负责人:CRAIG S LEVIN
-
依托单位:
Photon interaction depth encoded time-of-flight PET
-
批准号:8488439
-
项目类别:
-
资助金额:$18.0万
-
财政年份:2012
-
负责人:CRAIG S LEVIN
-
依托单位:
Preclinical Translation of New Scintillation Light Detection Concepts for PET
-
批准号:8248197
-
项目类别:
-
资助金额:$40.25万
-
财政年份:2011
-
负责人:CRAIG S LEVIN
-
依托单位:
海外基金