QUADRATURE, RF COIL ARRAYS FOR MUSCULOSKELETAL MRI

用于肌肉骨骼 MRI 的正交射频线圈阵列

基本信息

  • 批准号:
    2798251
  • 负责人:
  • 金额:
    $ 10万
  • 依托单位:
  • 依托单位国家:
    美国
  • 项目类别:
  • 财政年份:
    1999
  • 资助国家:
    美国
  • 起止时间:
    1999-04-05 至 2000-04-04
  • 项目状态:
    已结题

项目摘要

The work proposed is within the mission of the NIAMS. In Phase I, a novel volume RF coil array with a 30-40% improvement in S/N for high-resolution knee MRI will be developed at 1.5T. Frequently mode distributions will be observed and phantom measurements are planned during the six month project. Phase II will involve optimizing the knee coil, shrinking the design to an elliptically shaped coil for wrist imaging. Expansions to a while-body coil for hip imaging are also planned. All these coils will be evaluated with phantoms and volunteers rigorously, prior to patient use. A major technical focus is to further improve the S/N of a NMR experiment by a factor of 2. Potential clinical and research uses will be geared toward obtaining reliable, reproducible high-resolution images needed to enhance diagnostic accuracy in possibly reduced scan times, decreasing patient discomfort while increasing throughput in a MR scanner. This we believe will be of a substantial benefit to mankind. PROPOSED COMMERCIAL APPLICATION: Clinical applications include non-ionizing, non-invasive and a cost effective approach toward diagnosis of arthritis and musculoskeletal diseases of the knee, wrist & hand, foot & ankle and hip when compared to the invasive arthrography. This project will provide improvements to MR phased array coil technology, including sequence and technique optimizations. If clinical value is demonstrated, MR systems based on this technology will find widespread applications in imaging the human musculoskeletal system.
拟议的工作属于国家机构间监测系统的使命范围。在第I阶段,将在1.5T下开发一种新型容积RF线圈阵列,用于高分辨率膝关节MRI,信噪比提高30-40%。 在六个月的项目期间,将经常观察模式分布,并计划进行体模测量。第二阶段将涉及优化膝盖线圈,缩小设计为椭圆形线圈的手腕成像。 还计划扩展到用于髋关节成像的while-body线圈。 在患者使用前,所有这些线圈都将由体模和志愿者进行严格评价。一个主要的技术重点是进一步提高NMR实验的信噪比2倍。 潜在的临床和研究用途将面向获得可靠的,可重复的高分辨率图像,以提高诊断准确性,减少扫描时间,减少患者不适,同时增加MR扫描仪的吞吐量。 我们认为这将给人类带来重大利益。拟定商业应用:临床应用包括非电离,非侵入性和成本效益的方法来诊断关节炎和肌肉骨骼疾病的膝盖,手腕和手,脚和脚踝和髋关节相比,侵入性关节造影。 该项目将提供MR相控阵线圈技术的改进,包括序列和技术优化。 如果临床价值得到证实,基于该技术的MR系统将在人体肌肉骨骼系统成像中得到广泛应用。

项目成果

期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ monograph.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ sciAawards.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ conferencePapers.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ patent.updateTime }}

RAVI SRINIVASAN其他文献

RAVI SRINIVASAN的其他文献

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

{{ truncateString('RAVI SRINIVASAN', 18)}}的其他基金

NOVEL RF COIL DESIGN FOR HEAD/NECK TUMOR IMAGING AT 3T
用于 3T 头颈肿瘤成像的新型射频线圈设计
  • 批准号:
    6479270
  • 财政年份:
    2002
  • 资助金额:
    $ 10万
  • 项目类别:
QUADRATURE, RF COIL ARRAYS FOR MUSCULOSKELETAL MRI
用于肌肉骨骼 MRI 的正交射频线圈阵列
  • 批准号:
    6406164
  • 财政年份:
    2001
  • 资助金额:
    $ 10万
  • 项目类别:
QUADRATURE, RF COIL ARRAYS FOR MUSCULOSKELETAL MRI
用于肌肉骨骼 MRI 的正交射频线圈阵列
  • 批准号:
    6534449
  • 财政年份:
    2001
  • 资助金额:
    $ 10万
  • 项目类别:
MR COMPATIBLE ISOLETTE FOR IMAGING NEONATES
用于新生儿成像的 MR 兼容 ISOLETTE
  • 批准号:
    2732230
  • 财政年份:
    1999
  • 资助金额:
    $ 10万
  • 项目类别:
NOVEL RF COILS FOR IMAGING NEONATES
用于新生儿成像的新型射频线圈
  • 批准号:
    6643803
  • 财政年份:
    1999
  • 资助金额:
    $ 10万
  • 项目类别:
DUAL-TUNED PROBE FOR MRI/MRS OF THE HUMAN BRAIN
用于人脑 MRI/MRS 的双调谐探头
  • 批准号:
    2540516
  • 财政年份:
    1998
  • 资助金额:
    $ 10万
  • 项目类别:
IMPROVED, HEAD VOLUME PHASED ARRAY FOR NMR
用于 NMR 的改进头体积相控阵
  • 批准号:
    2537543
  • 财政年份:
    1998
  • 资助金额:
    $ 10万
  • 项目类别:
DUAL-TUNED PROBE FOR MRI/MRS OF THE HUMAN BRAIN
用于人脑 MRI/MRS 的双调谐探头
  • 批准号:
    6140908
  • 财政年份:
    1998
  • 资助金额:
    $ 10万
  • 项目类别:
DUAL-TUNED PROBE FOR MRI/MRS OF THE HUMAN BRAIN
用于人脑 MRI/MRS 的双调谐探头
  • 批准号:
    6393903
  • 财政年份:
    1998
  • 资助金额:
    $ 10万
  • 项目类别:
A HIGH S/N, VOLUME PHASED ARRAY FOR NMR
用于 NMR 的高信噪比大体积相控阵
  • 批准号:
    6363672
  • 财政年份:
    1997
  • 资助金额:
    $ 10万
  • 项目类别:
{{ showInfoDetail.title }}

作者:{{ showInfoDetail.author }}

知道了