课题基金 / 基金详情

项目摘要

项目成果

MARK A. ARNOLD的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): Two novel solid-state instrumental designs are described for use in the noninvasive measurement of blood glucose. Both instruments implement transmission measurements of near-infrared light through a tissue sample and allow the encoding of multivariate calibration models in hardware. Each instrument is based on the sequential measurement of pre-defined combinations of near- infrared wavelengths that are specified in the form of filter bandpass functions. In the two designs, these filter profiles are generated with either a digital micromirror array (MMA) or an acousto-optic tunable filter (AOT F). The MMA allows the specification of filter profiles of arbitrary complexity, while the AOTF allows the generation of filters with simpler square-wave shapes. A computational model and numerical optimization procedures are described for use in defining optimal filter profiles that result in the measurement of unique spectral patterns that are selective for blood glucose. These filter profiles are analogous to the components extracted by multivariate calibration models from contiguous spectral data acquired by a conventional spectrometer. Performing these discrete filter-based measurements gains both throughput and multiplex advantages, and allows the creation of rugged instrumental designs that are compatible with noninvasive blood glucose measurements made by diabetic patients outside the controlled environment of the laboratory. Both in vitro experiments and in vivo studies with a rat model are proposed for use in characterizing the performance and analytical utility of these instrumental designs. The experimental and computational work will be directed to the overall goal of developing a noninvasive nocturnal hypoglycemic alarm.
期刊论文(4)
专著(0)
科研奖励(0)
会议论文
DOI: 10.1021/ac802023w
发表时间: 2009-02
期刊: Analytical chemistry
影响因子: 7.4
作者: [T. Tarumi;Yuping Wu;G. W. Small]
通讯作者: T. Tarumi;Yuping Wu;G. W. Small
Design considerations for near-infrared filter photometry: effects of noise sources and selectivity.
近红外滤光片光度测定的设计注意事项:噪声源和选择性的影响。
DOI: 10.1366/000370209788559601
发表时间: 2009
期刊: Applied spectroscopy
影响因子: 3.5
作者: [Tarumi,Toshiyasu, Amerov,AiratK, Arnold,MarkA, Small,GaryW]
通讯作者: Small,GaryW
The charges for ESRD treatment of diabetics.
糖尿病患者终末期肾病 (ESRD) 治疗费用。
DOI: 10.1016/0895-4356(89)90084-x
发表时间: 1989
期刊: Journal of clinical epidemiology
影响因子: 7.2
作者: [Smith,DG, Harlan,LC, Hawthorne,VM]
通讯作者: Hawthorne,VM
Noninvasive Nocturnal Hypoglycemic Alarm
  • 批准号:
    7210503
  • 项目类别:
  • 资助金额:
    $49.19万
  • 财政年份:
    2007
  • 负责人:
    MARK A. ARNOLD
  • 依托单位:
Noninvasive Nocturnal Hypoglycemic Alarm
  • 批准号:
    7433856
  • 项目类别:
  • 资助金额:
    $47.54万
  • 财政年份:
    2007
  • 负责人:
    MARK A. ARNOLD
  • 依托单位:
Instrumental Designs for Near Infrared Glucose Monitors
  • 批准号:
    7034463
  • 项目类别:
  • 资助金额:
    $16.47万
  • 财政年份:
    2004
  • 负责人:
    MARK A. ARNOLD
  • 依托单位:
Instrumental Designs for Near Infrared Glucose Monitors
  • 批准号:
    6767316
  • 项目类别:
  • 资助金额:
    $19.86万
  • 财政年份:
    2004
  • 负责人:
    MARK A. ARNOLD
  • 依托单位:
海外基金