Reduced Afterglow Scintillator Films for High Speed Medical Imaging

Reduced Afterglow Scintillator Films for High Speed Medical Imaging
用于高速医学成像的减少余辉闪烁体薄膜
批准号:
7688127
负责人:
VIVEK V NAGARKAR
金额:
$68.34万
依托单位国家:
美国
项目类别:
财政年份:
2008
资助国家:
美国
项目状态:
已结题
起止时间:
2008-09-18 至 2011-07-31

项目摘要

项目成果

VIVEK V NAGARKAR的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): While many exotic new scintillation materials are now being developed, few even come close to CsI:Tl in performance and versatility. Widely available commercially at low cost, CsI:Tl not only has superb scintillation efficiency, but also can readily be fabricated as large-area microcolumnar films for high-resolution imaging, making it the material of choice for a wide range of applications. Unfortunately, CsI:Tl exhibits both a strong afterglow component in its scintillation decay and severe hysteresis after prolonged irradiation, limiting achiev- able energy resolution and imaging quality and speed. These shortcomings effectively preclude its use in applica- tions such as radionuclide imaging and medical CT, where its low cost could otherwise have immense economic impact. An improved form of CsI:Tl scintillator can reduce the cost of critical life-saving medical equipment such as X-ray CT scanners, fluoroscopy systems and other devices that rely on rapid data acquisition. In systematic studies of the cooperative effects of codopants in CsI:Tl, we have identified additives that can suppress its afterglow by as much as two orders of magnitude while maintaining its extraordinary scintillation properties. We also find that similar treatment can diminish hysteresis by more than a factor of ten, represent- ing a major breakthrough that has eluded researchers for decades. Moreover, we have clearly established that, through a co-evaporation technique, we can deposit thick microcolumnar films of this modified material, which provide very high spatial resolution appropriate for such new and exciting applications as "nanoSPECT" and high-speed cone-beam CT using flat panel detectors. With these exceptional properties, codoped CsI:Tl is now poised for exploitation in many rapid imaging modalities from which CsI:Tl had been previously excluded. But while we have achieved all these desirable effects in melt-grown crystals, we have not yet combined them at satisfactory levels at a single film composition; this is the specific goal of Phase I. Having already established the feasibility of the multicomponent deposition process itself, we will reach this goal through careful and system- atic variation of deposition parameters such as source and substrate temperatures, source-substrate distances, and chemical make-up of the sources themselves. Phase I will produce material with scintillation properties at least as good as in melt-grown single crystals, thereby becoming immediately useful for commercial evaluation. Phase II has far more comprehensive goals than Phase I. Here we will seek to optimize the material in terms of both chemical composition and physical morphology. In addition, guided by the results of Phase I and input from substantial new theoretical support, we will seek to understand both the mechanisms responsible for the observed effects and the kinetic factors that govern the deposition process itself. Cognizant of their ultimate applications, we will grow microcolumnar films of various dimensions ranging from 5 x 5 cm2 to 50 x 50 cm2, and demonstrate their utility by evaluating film performance in CBCT and SPECT modes of operation. Finally, we will promote commercialization through cooperative programs with potential users of this technology. PUBLIC HEALTH RELEVANCE: The widely available, low cost CsI:Tl not only has superb scintillation efficiency, but also can readily be fabricated as large-area microcolumnar films for high-resolution imaging, making it the material of choice for a wide range of applications. Unfortunately, CsI:Tl exhibits both a strong afterglow component in its scintillation decay and severe hysteresis after prolonged irradiation, limiting achievable energy resolution and imaging quality and speed. These shortcomings effectively preclude its use in applications such as radionuclide imaging and medical CT, where its low cost could otherwise have immense economic impact. An improved form of CsI:Tl scintillator, such as the one proposed here, can reduce the cost of critical life-saving medical equipment such as X-ray CT scanners, fluoroscopy systems and other devices that rely on rapid data acquisition.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Novel High Resolution Scintillator for Imaging Bone Microarchitecture in Flat Panel Cone Beam CT
Dual Mode, Hand-held Intraoperative Imager
Dual Mode, Hand-held Intraoperative Imager
New Design of a Sensor for Ultrahigh Performance SPECT Imaging
国内基金
海外基金
层出镰刀菌氮代谢调控因子AreA 介导伏马菌素 FB1 生物合成的作用机理
  • 批准号:
    2021JJ40433
  • 项目类别:
    省市级项目
  • 资助金额:
    --
  • 批准年份:
    2021
  • 负责人:
    孙磊
  • 依托单位:
寄主诱导梢腐病菌AreA和CYP51基因沉默增强甘蔗抗病性机制解析
  • 批准号:
    32001603
  • 项目类别:
    青年科学基金项目
  • 资助金额:
    24.0万元
  • 批准年份:
    2020
  • 负责人:
    段真珍
  • 依托单位:
AREA国际经济模型的移植.改进和应用
  • 批准号:
    18870435
  • 项目类别:
    面上项目
  • 资助金额:
    2.0万元
  • 批准年份:
    1988
  • 负责人:
    史树中
  • 依托单位: