High performance SPECT System for Cardiac Imaging
High performance SPECT System for Cardiac Imaging
批准号:
10064098
负责人:
Hamid Sabet
金额:
$77.71万
依托单位国家:
美国
项目类别:
财政年份:
2018
资助国家:
美国
项目状态:
已结题
起止时间:
2018-12-15 至 2023-11-30
关键词:
AreaArizonaBiological ModelsBody mass indexCaliberCalibrationCardiacCardiac VolumeCause of DeathClinicalCollimatorComputer softwareCoronary ArteriosclerosisCrystallizationDCNUDevelopmentDiscipline of Nuclear MedicineElectrocardiogramElectronicsElementsEvaluationFloodsGamma CamerasGamma RaysGeometryGoalsGrantHeadHealth Care CostsHeartHospitalsImageLasersLengthLesionManufacturer NameMapsMeasuresMechanicsMedical centerMethodsModelingMorbidity - disease rateMorphologic artifactsObesityOpticsOrganPatientsPatternPerformancePhysicians&apos OfficesPhysiologic pulsePositioning AttributePositron-Emission TomographyPriceProceduresProcessRecoveryReportingResearch Project GrantsResearch ProposalsResolutionRestSamplingScanningSemiconductorsSideSiliconSourceSystemSystems IntegrationTechniquesThallium Myocardial Perfusion Imaging Stress TestThickTimeattenuationbasecardiac single photon emission computed tomographycostcost effectivedensitydesigndetectordiagnostic accuracydigitalheart imaginghigh resolution imagingimage reconstructionimagerimaging modalityimaging studyimprovedinnovationmortalityprototypereconstructionscreeningsensorsingle photon emission computed tomographysocialstatisticstrend
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Abstract
Single Photon Emission Computed Tomography (SPECT) is still the mainstay for cardiac screening. Current
state of the art cardiac SPECT systems (Spectrum-Dynamic's D-SPECT and GE's Discovery NM530) use CZT
semiconductor detectors which results in a number of cost-performance tradeoffs. They are based on the use of
large collimator holes (compared with collimators used in standard dual head gamma camera) to increase the
system sensitivity that may result in poor image resolution when no resolution recovery applied. The main
objective of this project is to develop a high-sensitivity and high-spatial resolution SPECT system for cardiac
applications. To make such an organ-specific SPECT system widely available however, the development cost
has to be practical so that the system acquisition by the medical centers, hospitals and even physician offices is
not cost-prohibitive. It should be mentioned that the CZT-based systems are much more expensive than a
standard dual head gamma-camera. In this grant we plan to improve the performance of Cardiac SPECT without
increasing the development cost. In order to achieve our goals we envision a SPECT system build from 8-10
mm thick conventional scintillators (CsI:Tl or NaI:Tl) with one-sided readout using silicon multipliers (SiPM)
arrays. Owing to their high density, availability, and price which is at least an order of magnitude smaller than
CZT, CsI (or NaI) is an attractive scintillator to use for out project. Our goal is to achieve high spatial image
resolution and 0.1% scanner sensitivity which is about 10-times larger than dual-head gamma camera. We will
utilize laser-induced optical barriers (LIOB) technique to fabricate the scintillator arrays.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
High-performance SPECT for dynamic brain imaging
-
批准号:10718519
-
项目类别:
-
资助金额:$63.85万
-
财政年份:2023
-
负责人:Hamid Sabet
-
依托单位:
High-Performance Positron Emission Tomography for brain imaging
-
批准号:9894405
-
项目类别:
-
资助金额:$8.31万
-
财政年份:2019
-
负责人:Hamid Sabet
-
依托单位:
High performance SPECT System for Cardiac Imaging
-
批准号:10527342
-
项目类别:
-
资助金额:$65.8万
-
财政年份:2018
-
负责人:Hamid Sabet
-
依托单位:
High performance SPECT System for Cardiac Imaging
-
批准号:10312007
-
项目类别:
-
资助金额:$79.26万
-
财政年份:2018
-
负责人:Hamid Sabet
-
依托单位:
Novel laser-processed scintillation detector for high-resolution PET scanners
-
批准号:9197984
-
项目类别:
-
资助金额:$21.77万
-
财政年份:2015
-
负责人:Hamid Sabet
-
依托单位:
Novel tileable scintillator-based photon counting detector for clinical X-ray CT
-
批准号:9132245
-
项目类别:
-
资助金额:$8.7万
-
财政年份:2015
-
负责人:Hamid Sabet
-
依托单位:
Novel laser-processed scintillation detector for high-resolution PET scanners
-
批准号:9034768
-
项目类别:
-
资助金额:$26.99万
-
财政年份:2015
-
负责人:Hamid Sabet
-
依托单位:
Novel tileable scintillator-based photon counting detector for clinical X-ray CT
-
批准号:8952025
-
项目类别:
-
资助金额:$8.7万
-
财政年份:2015
-
负责人:Hamid Sabet
-
依托单位:
海外基金