Development of CT to simultanously detect scattering x-ray, fluorescent x-ray and transmission x-ray

Development of CT to simultanously detect scattering x-ray, fluorescent x-ray and transmission x-ray
开发同时检测散射X射线、荧光X射线和透射X射线的CT
批准号:
06507002
负责人:
ITAI Yuji
金额:
$26.05万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Developmental Scientific Research (A)
财政年份:
1994
资助国家:
日本
项目状态:
已结题
起止时间:
1994 至 1995

项目摘要

项目成果

ITAI Yuji的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
A computed tomography (CT) to simultanously detect scattering x-ray, fluorescent x-ray and transmission x-ray was developed. The interaction between the object and x-ray generated the scattering x-ray, fluorescent x-ray and transmission x-ray. In clinical practise, only the transmission x-ray is used to diagnose the disease. In this experiment we developed new type of CT to detect all information of x-ray interaction with object. Experiment was performed at bending magnet beam line ARNE 5A in KEK.1. Fluorescent x-ray CT image : Specific element as iodine was detected as presently used single photon emission CT.Minimal detectable dose was 50ng iodine by fan collimator fluorescent-CT system using large diameter germanium detector.2. Scattering x-ray CT image : Incoherent x-ray (Compton) and coherent x-ray (Thomson) CT imaging was obtained in the phantom by multi-channel germanium detector. Thomson CT image can demonstrate the difference of elements such as oil, water, calcium and contrast material. Compton CT can demonstrate the differnce of electron density of material.3. Transmission x-ray image : Using CCD detector, fine stracture of the phantom was revealed. Detectable concentration of iodine contrast material was 200 microgram/ml in 1 mm slice thickness.A new type of CT to detect all information of x-ray interaction was developed and this system is thought to reveal various informations of object simultaniously.
期刊论文(28)
专著(0)
科研奖励(0)
会议论文
Takeda T,Itai Y,Yoshioka H,Umetani K,Ueda K,Akisada M.: "Synchrotron radiation cine K-edge energy subtraction coronary arteriography using an iodine filter method" Medical & Biological Engineering & Computing. 32. 462-468 (1994)
Takeda T,Itai Y,Yoshioka H,Umetani K,Ueda K,Akisada M.:“使用碘过滤方法的同步辐射电影 K 边缘能量减法冠状动脉造影”医疗
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Takeda T,Ito T,Kishi K,Maeda T,Yuasa T,Wu J,Kazama M,Hyodo K,Akatsuka T,Itai Y.: "Preliminary experiment of the fluorescent x-ray computed tomography with synchrotron radiation" Medical Imaging Technology. 12 (4). 537-538 (1994)
Takeda T,Ito T,Kishi K,Maeda T,Yuasa T,Wu J,Kazama M,Hyodo K,Akatsuka T,Itai Y.:“同步辐射荧光X射线计算机断层扫描的初步实验”医学成像技术。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Takeda T,Maeda T,Yuasa T,et.al.: "Fluorescent scanning x-ray tomographic image with monochromatic synchrotron x-ray." Medical Imaging Technology.14. 183-194 (1996)
Takeda T、Maeda T、Yuasa T 等人:“单色同步加速器 X 射线荧光扫描 X 射线断层扫描图像。”
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
武田徹: "放射光を利用した微量元素分析型CT開発" 新医療. 230. 72-76 (1994)
Toru Takeda:“使用同步加速器辐射进行微量元素分析的 CT 的开发”《新医学》230. 72-76 (1994)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
18
    Development of high-sensitive synchrotron x-ray micro CT
    • 批准号:
      12307018
    • 项目类别:
      Grant-in-Aid for Scientific Research (A)
    • 资助金额:
      $9.07万
    • 财政年份:
      2000
    • 负责人:
      ITAI Yuji
    • 依托单位:
    Development of phase contrast x-ray imaging system
    The development of monochromatic X-ray computed tomography with synchrotron radiation
    • 批准号:
      05404037
    • 项目类别:
      Grant-in-Aid for General Scientific Research (A)
    • 资助金额:
      $21.25万
    • 财政年份:
      1993
    • 负责人:
      ITAI Yuji
    • 依托单位:
    Research on MRI Contrast Agents for the Liver.
    海外基金