Improved C-Arm CT for Interventional Procedures

Improved C-Arm CT for Interventional Procedures
改进的 C 型臂 CT 用于介入手术
批准号:
7009290
负责人:
Rebecca Fahrig
金额:
$38.32万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2004
资助国家:
美国
项目状态:
已结题
起止时间:
2004-03-15 至 2008-01-31

项目摘要

项目成果

Rebecca Fahrig的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): Minimally invasive procedures using endovascular access under x-ray fluoroscopic guidance have enabled treatment of patients that previously had no options. Even in patients who may be surgical candidates, minimally invasive procedures may be preferred because of their lower risk, faster recovery, and lower cost. Among these applications are the treatment of abdominal aortic aneurysms using stents and intracranial interventions with thrombolytic and embolic agents. Guidance using x-ray fluoroscopy is well-suited for many aspects of these procedures, however it is unable to depict a number of potential complications, such as endoleaks (which occur in 20-30% of aortic stents) or intracranial bleeding, nor to fully explore hemodynamic parameters such as blood volume. Often, patients require follow-up CT scans. While tomographic imaging using C-arms is being used for imaging high-contrast objects, basic problems have prevented these systems from providing sufficient low contrast sensitivity for a number of important tasks. We propose to greatly improve the low-contrast performance of C-arm CT, and thereby provide both x-ray fluoroscopy and much higher quality C-arm-based CT images during interventional procedures. The improved C-arm CT will bring low contrast resolution approaching that of conventional CT into the interventional lab and improve image guidance for these procedures. We will address problems such as scatter, under-sampling and beam hardening, and develop hardware and software to improve low-contrast detection with the specific goal of detecting a 10 mm object of 40 HU contrast (+/-10 HU noise). We will optimize acquisition and measurement protocols for the guidance of abdominal aortic stenting and intracranial interventions, and test these in vitro and in a porcine model. We expect to demonstrate the ability to depict the relationship among a stent and the vessel wall and thrombus, to visualize endoleaks, to estimate blood volume, and to detect fresh intracranial bleeds. The significance of this project is amplified by the fact that the technology developed here could eventually impact many other minimally invasive procedures.
期刊论文(18)
专著(0)
科研奖励(0)
会议论文
DOI: 10.1118/1.3397463
发表时间: 2010-05
期刊: Medical physics
影响因子: 3.8
作者: [Sungwon Yoon;A. Pineda;R. Fahrig]
通讯作者: Sungwon Yoon;A. Pineda;R. Fahrig
An efficient estimation method for reducing the axial intensity drop in circular cone-beam CT.
一种减少圆锥束CT轴向强度下降的有效估计方法。
DOI: 10.1155/2008/242841
发表时间: 2008
期刊: International journal of biomedical imaging
影响因子: 7.6
作者: [Zhu L, Starman J, Fahrig R]
通讯作者: Fahrig R
A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors.
非晶硅平板 X 射线探测器的非线性滞后校正算法。
DOI: 10.1118/1.4752087
发表时间: 2012
期刊: Medical physics
影响因子: 3.8
作者: [Starman,Jared, Star-Lack,Josh, Virshup,Gary, Shapiro,Edward, Fahrig,Rebecca]
通讯作者: Fahrig,Rebecca
DOI: 10.1118/1.2789405
发表时间: 2007-11
期刊: Medical physics
影响因子: 3.8
作者: [Lei Zhu;Sungwon Yoon;R. Fahrig]
通讯作者: Lei Zhu;Sungwon Yoon;R. Fahrig
MR-Compatible Linac Gun for Robotic Linac Adaptation
  • 批准号:
    8413455
  • 项目类别:
  • 资助金额:
    $20.17万
  • 财政年份:
    2013
  • 负责人:
    Rebecca Fahrig
  • 依托单位:
Dual kV/MV Imaging for Metal Artifact Reduction
  • 批准号:
    7886175
  • 项目类别:
  • 资助金额:
    $74.83万
  • 财政年份:
    2010
  • 负责人:
    Rebecca Fahrig
  • 依托单位:
Dual kV/MV Imaging for Metal Artifact Reduction
  • 批准号:
    8063158
  • 项目类别:
  • 资助金额:
    $66.91万
  • 财政年份:
    2010
  • 负责人:
    Rebecca Fahrig
  • 依托单位:
Axiom zeego shared instrument grant
  • 批准号:
    7792710
  • 项目类别:
  • 资助金额:
    $50.0万
  • 财政年份:
    2010
  • 负责人:
    Rebecca Fahrig
  • 依托单位:
海外基金