CPS: Medium: Collaborative Research: Cyber-Enabled Online Quality Assurance for Scalable Additive Bio-Manufacturing
CPS: Medium: Collaborative Research: Cyber-Enabled Online Quality Assurance for Scalable Additive Bio-Manufacturing
批准号:
1739696
负责人:
Prahalada Rao
金额:
$20.0万
依托单位国家:
美国
项目类别:
Standard Grant
财政年份:
2017
资助国家:
美国
项目状态:
已结题
起止时间:
2017-09-01 至 2023-01-31
中文摘要
如果有足够数量的器官,仅在美国,每年就可以通过器官移植挽救近100万人的生命,这可能会避免美国35%的死亡。相比之下,由于器官严重短缺,每年只有大约2.8万例器官移植手术,等待移植的人数达到12万人。解决这一短缺的一个有希望的潜在解决方案是通过生物增材制造(Bio-AM)对人体器官进行高质量和生产规模的3D打印。然而,正如2016年NSF关于医疗保健增材制造的研讨会所阐述的那样,目前Bio-AM的使用受到器官质量差的阻碍,部分原因是过程监控不足和缺乏综合过程控制策略。因此,尽管取得了巨大的进步,但仍不可能将Bio-AM扩展到器官移植所需的严格质量标准。这项研究将解决迫切需要将先进的过程模型纳入基于传感器的过程控制策略中,以防止细胞损伤,减少细胞放置错误,并改善Bio-AM中的组织功能。如果能够实现可靠、大批量、高质量和安全的Bio-AM的成功方法,它将在公共卫生、医疗安全和药物发现方面产生深远的社会经济效益。该项目将通过教师研究经验(RET)创新制造计划吸引6-12年级的STEM教师,为教师提供参与Bio-AM前沿研究的机会。该项目的目标是可靠地生产可行的3D打印生物结构(微型组织)。核心方法是将基于异构传感器的原位监测和实时闭环过程控制方法相结合,以确保生物结构的可靠打印。这项工作包括以下四个目标:(1)通过实验和建模来了解工艺-材料相互作用对特定Bio-AM缺陷的因果关系;(2)使用传感器来检测打印过程中的早期缺陷;(3)通过实时决策理论模型分析传感器数据来诊断检测到的缺陷的根本原因;(4)通过闭环过程控制来防止缺陷的传播。调查将有助于:(1)通过实证研究和基于传感器的数据分析,对控制打印生物组织结构质量的因果生物物理过程相互作用的基本理解;(2)考虑复杂和动态的组织成熟现象,预测层质量的新数学模型;(3)实时和计算高效的决策,用于从传感器数据中准确分类缺陷;通过在印刷过程中执行智能纠正措施来防止缺陷传播的闭环质量控制方法。
英文摘要
Close to one million lives could be saved each year in the United States alone by organ transplantation if a sufficient number of organs were available, potentially preventing 35% of all deaths in the nation. In contrast, due to critical shortages of organs, only about 28,000 organ transplants are performed each year, with a waiting list of 120,000 people. A promising potential solution to this shortage is the high quality and production-scale 3D printing of human organs by bio-additive manufacturing (Bio-AM). However, as articulated in the 2016 NSF workshop on Additive Manufacturing for Healthcare, the current use of Bio-AM is impeded by poor organ quality, resulting in part from inadequate process monitoring and lack of integrated process control strategies. As a result, despite enormous strides, it is still not possible to scale Bio-AM to the stringent quality standards mandated for organ transplants. This research will address the compelling need to incorporate advanced process models into sensor-based process control strategies needed to prevent cell damage, decrease cell placement errors, and improve tissue functioning in Bio-AM. If successful methods for reliable, high-volume, high-quality, and safe Bio-AM can be realized, it will have profound socioeconomic benefits in terms of public health, medical safety, and drug discovery. The project will engage grade 6-12 STEM teachers through the Research Experiences for Teachers (RET) Innovation-based Manufacturing Program by providing opportunities for teachers to engage in cutting edge research in Bio-AM. The goal of the project is to reliably produce viable 3D printed biological constructs (mini-tissues). The central approach is to couple in-situ heterogeneous sensor-based monitoring and real-time closed-loop process control approaches for ensuring the reliable printing of biological constructs. The work involves the following four objectives: (1) using experimentation and modeling to understand the causal effect of process-material interactions on specific Bio-AM defects, (2) employing sensors to detect incipient defects during printing, (3) diagnosing the root causes of detected defects by analyzing sensor data using real-time decision-theoretic models, and (4) preventing propagation of defects through closed-loop process control. The investigation will contribute: (1) fundamental understanding of the causal bio-physical process interactions that govern the quality of printed biological tissue constructs through empirical investigation and sensor-based data analytics, (2) new mathematical models for predicting the layer quality by taking into consideration the complex and dynamic tissue maturation phenomena, (3) real-time and computationally efficient decision-making for accurate classification of defects from sensor data, and (4) a two-stage, real-time, closed-loop quality control approach for preventing propagation of defects by executing smart corrective actions during the printing process.
期刊论文(4)
专著(0)
科研奖励(0)
会议论文
DOI:
10.1016/j.bprint.2020.e00116
发表时间:
2021-03-01
期刊:
Bioprinting
影响因子:
--
作者:
[Ramesh, Srikanthan, Harrysson, Ola L. A., Rivero, Iris, V]
通讯作者:
Rivero, Iris, V
DOI:
10.1007/s10845-023-02092-6
发表时间:
2023-03-06
期刊:
JOURNAL OF INTELLIGENT MANUFACTURING
影响因子:
8.3
作者:
[Gerdes,Samuel, Gaikwad,Aniruddha, Rao,Prahalada]
通讯作者:
Rao,Prahalada
PFI-TT: Ultrafast Thermal Simulation of Metal Additive Manufacturing
-
批准号:2322322
-
项目类别:Standard Grant
-
资助金额:$25.0万
-
财政年份:2023
-
负责人:Prahalada Rao
-
依托单位:
CAREER: Smart Additive Manufacturing - Fundamental Research in Sensing, Data Science,and Modeling Toward Zero Part Defects.
-
批准号:2309483
-
项目类别:Standard Grant
-
资助金额:$50.0万
-
财政年份:2022
-
负责人:Prahalada Rao
-
依托单位:
PFI-TT: Ultrafast Thermal Simulation of Metal Additive Manufacturing
-
批准号:2044710
-
项目类别:Standard Grant
-
资助金额:$25.0万
-
财政年份:2021
-
负责人:Prahalada Rao
-
依托单位:
RII Track-4: Understanding the Fundamental Thermal Physics in Metal Additive Manufacturing and its Influence on Part Microstructure and Distortion.
-
批准号:1929172
-
项目类别:Standard Grant
-
资助金额:$14.86万
-
财政年份:2020
-
负责人:Prahalada Rao
-
依托单位:
CAREER: Smart Additive Manufacturing - Fundamental Research in Sensing, Data Science,and Modeling Toward Zero Part Defects.
-
批准号:1752069
-
项目类别:Standard Grant
-
资助金额:$50.0万
-
财政年份:2018
-
负责人:Prahalada Rao
-
依托单位:
Biosensor Data Fusion for Real-Time Monitoring of Global Neurophysiological Function
-
批准号:1719388
-
项目类别:Standard Grant
-
资助金额:$21.3万
-
财政年份:2016
-
负责人:Prahalada Rao
-
依托单位:
Biosensor Data Fusion for Real-Time Monitoring of Global Neurophysiological Function
-
批准号:1538059
-
项目类别:Standard Grant
-
资助金额:$21.8万
-
财政年份:2015
-
负责人:Prahalada Rao
-
依托单位:
海外基金