课题基金 / 基金详情

Cooling Suit for First Responders

Cooling Suit for First Responders
急救人员的冷却服
批准号:
7404632
负责人:
GIRISH SRINIVAS
金额:
$10.0万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2007
资助国家:
美国
项目状态:
已结题
起止时间:
2007-09-01 至 2008-09-30

项目摘要

项目成果

GIRISH SRINIVAS的其他基金

相似基金

相关文献

中文摘要
翻译
描述(由申请人提供):当应对化学品泄漏或其他危险清理操作时,第一响应者必须经常穿着a级危险品防护服。这些防护服通过完全密封穿着者免受外部蒸汽和液体的侵害,保护第一响应者免受化学物质的暴露。因为宇航服是密封的,所以需要新鲜空气供应,通常由自给式呼吸器(SCBA)提供。总的来说,SCBA/不渗透宇航服提供了不含污染物的空气和化学危害的屏障。不幸的是,由于宇航服是密封的,它们很快就会变得非常炎热和潮湿。考虑到第一响应者可以在宇航服中呆30-60分钟,过热不仅是不适的来源,而且是对第一响应者健康的真正危害。此外,汗水会凝结在面板内部,遮挡视线,而宇航服中的热量/湿度会严重限制穿着宇航服的时间,否则会有中暑的风险。
英文摘要
DESCRIPTION (provided by applicant): When responding to a chemical spill or other hazardous cleanup operation, first responders must frequently wear a level A hazardous materials suit. These suits protect the first responder from chemical exposure by completely sealing the wearer against external vapors and liquids. Because the suits are sealed, a fresh air supply is required which is typically provided by a self-contained breathing apparatus (SCBA). In total, the SCBA/impermeable suit provides contaminant free air and a barrier to the chemical hazard. Unfortunately, because the suits are sealed, they quickly get very hot and humid. Given the fact that a first responder can be in the suit from 30-60 min, overheating is not just a source of discomfort, but is a real hazard to the health of the first responder. In addition, perspiration condenses on the inside of the faceplate obscuring vision, and the heat/humidity buildup in the suit severely limits the time that can be spent in the suit without risking heat exhaustion. TDA Research, Inc. (TDA) proposes to develop a lightweight, portable system that will both cool and dehumidify the air circulated through a hazmat suit. TDA will use a heat exchanger to transfer heat from the inside of the suit to the dirty environment, but keeps the clean and contaminated air streams separate. The dry (about 15% RH) clean air is cooled to about 770F and returned to the first responder. The cool, dry air is distributed to the hands, head, and feet within the Personal Protective Equipment (PPE) with a lightweight fabric, internal duct system. In the Phase I project, we will design and build a test heat exchanger to demonstrate our concept. In addition, we will perform a system analysis using a 2D software and a finite element analysis. The design analysis will form the basis of the prototype fabrication in the Phase II project.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Advanced Pediatric Airway Trainer for Enhanced Clinical Education in Pediatric Critical Care
  • 批准号:
    10603760
  • 项目类别:
  • 资助金额:
    $30.0万
  • 财政年份:
    2023
  • 负责人:
    GIRISH SRINIVAS
  • 依托单位:
Improved Respirator Carbons for Ammonia Hazards
  • 批准号:
    9139745
  • 项目类别:
  • 资助金额:
    $15.0万
  • 财政年份:
    2016
  • 负责人:
    GIRISH SRINIVAS
  • 依托单位:
Antimicrobial Coatings to Reduce Hospital Infections
  • 批准号:
    8906076
  • 项目类别:
  • 资助金额:
    $14.37万
  • 财政年份:
    2015
  • 负责人:
    GIRISH SRINIVAS
  • 依托单位:
End-of-Service Life Indicator (ESLI)
  • 批准号:
    8715240
  • 项目类别:
  • 资助金额:
    $46.76万
  • 财政年份:
    2014
  • 负责人:
    GIRISH SRINIVAS
  • 依托单位:
海外基金